PZ-50HV2, PZ-50HV2E
PZ-50HV2U
2. General Information of the Plasma Display and AVC System
Display example of the first page
1 / 1 3
1
CENTE
2
OSD Ve r s i on
3
CV I C Ve r s i on
4
TTXP Ve r s i on
5
MON I TOR Ve r s i on
6
PANEL Ve r s i on
7
FLASH Ve r s i on
8
MON I TOR Mode l
9
Mod e l S l e
10
Mod e l S l e
11
Mod e l S l e
12
Sen so r e Temp
13
Cen t e r
14
15
Mon i t o r Ac u t i me
16
17
Pu l s e Ac u t i me
18
No.
1
Main software version information of the AVC System
2
OSD version information of the AVC System
IP/resize IC control software version information of the AVC
3
System
Text microcomputer software version information of the
4
AVC System
5
Module microcomputer software version information of the PDP
6
Panel microcomputer version information of the PDP
7
Panel flash ROM version information of the PDP
8
PDP model information
9
AVC System model information
10
AVC System model information
11
PDP destination information
Temperature information of panel temperature sensor on
12
the PDP
13
AVC System accumulation operating time
14
AVC System accumulation operating time reset
15
PDP accumulation operating time
16
PDP accumulation operating time reset
17
PDP accumulation pulse number
18
PDP accumulation pulse number reset
: Be careful so that there is the case that page constitution is different.
R Ve r s
i on
MR M I A N
MR O D
S
2
W2 0 0 / 1 0 9
TTX
P G
R
F6 9 1 1 0
- 0 0
- 0 5
0 1
e
c t
Ma
i n
0
e
c t AV
4
e
c t
MON I TOR
0
+
2 8
A
cu
t ime
1 6
RESET
OFF
4 7
RESET
OFF
1 6 4
RESET
OFF
Item
I
NP
U
T
1
No
S
I
G
E
2
0 0
1
/
0
9 /
2 5 H
0
0 1
/
0
9
/
1 0
A
/
1 2
0
9 :
0 0
X2 0 0 / 1 0 9
/
1 2
0
9 :
0 7
H
4 1 M
H
4 2 M
Reference
01: PIONEER 50 inches, 02: PIONEER 43 inches,
11: SHARP 50 inches, 12: SHARP 43 inches
0: All SHARP destinations, Japanese and North America destinations of
PIONEER, 3: European and general destinations of PIONEER
This is internal temperature information. This is not establishment
environment temperature.
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0H]
when pressing the "ENTER" key.
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0H]
when pressing the "ENTER" key.
Real accumulation pulse number becomes "indicated value *10,000,000 pulse".
Turn the display to [ON] by pressing the "VOL +" key, then it becomes [0]
when pressing the "ENTER" key.