Metrologic MK2320KD-60B241 - MS 2320 Stratos H Installation And User Manual page 48

Scanner / diva scale
Table of Contents

Advertisement

S
O
CALE
PERATION
C
ALIBRATION
Scale Calibration Procedure (lbs. or kg) with Remote Display*
4.
Reinstall the platter onto the scanner/scale.
5.
Go to Group 1 Step 8 (Weight Unit) of the Service Mode by pressing the Zero (
'Group 1 Step 8' is displayed on the Remote Scale Display screen (see Figure 46 below).
X Depending on the current Weight Unit setting, this value will either be 1, 2, 3, or 4.
6.
Verify the weight unit setting. Verify the Group 1 Step 8 setting using the table shown below. Press the Zero (
if correct. If the lb (Pounds) or kg (Kilograms) basic range setting needs to be changed, press the Tare (
through the selectable options. Press the Zero (
Group 1.Step 8 (1.8)
**
Common ranges used as default setting.
* These procedures are for MS2320 StratosH Scanner/Diva Scale models only
42
Figure 45. Install Platter
Figure 46. Remote Scale Display Group 1 Step 8 example shown
) key to accept the selected weight unit range.
1
lbs range (0 to 30 lbs) **
2
kg range (0 to 15kg)
3
kg multi-interval (0 to 6kg, 6 to 15kg) **
4
lbs multi-interval (0 to 15 lbs, 15 to 30 lbs)
Selectable Weight Unit Ranges
.
) key several times until
) key to scroll
) key