Download Print this page

KUSSMAUL 091-155 Installation And Operation Manual page 2

Automatic safety lock, 3 outputs

Advertisement

+12 volt
Power
Output #3
Output #2
+12 V
Brake
Light
Switch
Brake
Light
INSTALLATION:
1.
Mount unit in a suitable location protected from moisture and excessive heat.
2. Wire in accordance with the wiring diagram above
OPERATION:
1. With the engine running depress the momentary SET switch S1. The relay will close, the LED will be
illuminated and the engine will continue to run when the key is removed.
2. Remove the key from the ignition. The LED will continue to be illuminated and the engine will continue
to run.
3. Step on the foot brake. The LED will go out and the engine will stop.
4. Start the engine and repeat step 1.
5. Insert the key, turn ignition switch to ON and verify that the en gine continues to run when the brake
pedal is depressed.
SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS
KUSSMAUL ELECTRONICS COMPANY, INC.
170 CHERRY AVENUE, WEST SAYVILLE, NEW YORK, 11796-1221 USA
March 11, 2003
The common terminal of Relay K1
must be connected to the +12 volt
power for the unit to operate
N.C.
N.O.
COM.
K3
K2
This line resets
A Controller To Permit Engine Operation With The Ignition Switch Removed
INSTALLATION AND WIRING INSTRUCTIONS
IGNITION SWITCH
N.C.
N.O.
COM.
K1
1 2 3 4 5
(bypasses ignition)
Indicator illuminates when ignition
switch is bypassed
NOTE: Output 2 and Output 3 provide +12 volts to
accessories when SAFETY LOCK 3 is activated
MODEL 091-155
SAFETY LOCK 3
TEL:
SET
PUSHBUTTON
S1
(OPTIONAL)
631-567-0314,
FAX:
631-567-5826,
To Ignition
System

Advertisement

loading

This manual is also suitable for:

Safety lock 3091-155-12