Dimplex S1 7KS Installation And Operating Instructions Manual
Dimplex S1 7KS Installation And Operating Instructions Manual

Dimplex S1 7KS Installation And Operating Instructions Manual

Brine-to-water heat pump for indoor installation

Advertisement

OPERATING INSTRUCTIONS

Brine-to-Water Heat Pump
for Indoor Installation
Order No.: 452231.67.01
INSTALLATION and
SI 7KS
SI 9KS
CE
SI 11KS
SI 14KS
1
FD 8504

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S1 7KS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dimplex S1 7KS

  • Page 1: Operating Instructions

    INSTALLATION and OPERATING INSTRUCTIONS Brine-to-Water Heat Pump for Indoor Installation SI 7KS SI 9KS Order No.: 452231.67.01 SI 11KS SI 14KS FD 8504...
  • Page 2: Table Of Contents

    CONTENTS PLEASE READ IMMEDIATELY Important Information Legal Provisions and Directives Energy-Efficient Use of the Heat Pump PURPOSE OF THE HEAT PUMP Application Principle of Operation BASELINE UNIT ACCESSORIES Brine Manifold Brine Pressostat TRANSPORT INSTALLATION General Information Sound Emissions MOUNTING General...
  • Page 3: Please Read Immediately

    VDE, EN and IEC standards. Beyond that, the connection requirements of the local utility compa- nies have to be observed. The heat pump is to be connected to the heat source and heat distribution systems in accordance with all applicable provisions.
  • Page 4: Purpose Of The Heat Pump

    A circulating pump then conveys the warmed brine to the evaporator of the heat pump. There, the heat is given off to the refrigerant in the refrigeration cycle. When so doing, the brine cools so that it can again take up heat energy in the brine circuit.
  • Page 5: Accessories

    4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes.
  • Page 6: Installation Mounting

    Provided the controller and the heating circulating pumps are ready for operation, the frost protection function of the controller is always activated. If the heat pump is taken out of service or in the event of a power failure, the system must be drained. In heat...
  • Page 7: Connection On Heat Source Side

    Connection of the control voltage wire to the control panel of the heat pump. All electrical components required for the operation of the heat pump are located on the control panel.. For detailed instructions concerning the connection of external components and the operation of the heat pump controller refer to the heat pump terminal dia- gram and the operating manual of the controller.
  • Page 8: Commissioning

    - Drainage of the liquid emerging from the brine and heating water overflow valves must be ensured. 8.3 Commissioning Procedure The start-up of the heat pump is effected via the heat pump controller. CAUTION! Commissioning of the heat pump must be carried out in accordance with the installation and operating manual of the heat pump controller.
  • Page 9: Cleaning Of Heat Source Side

    9.3 Cleaning of Heat Source Side CAUTION! The supplied strainer is to be install- ed in the heat source inlet of the heat pump in order to protect the evaporator against conta- mination. The filter screen of the strainer should be cleaned one day after commissioning, thereafter every week.
  • Page 10 APPENDIX APPENDIX 12.1 DIMENSIONED DRAW- 12.2 EQUIPMENT DATA 12.3 SCHEMATICS 12.3.1 Characteristics .. 7KS 12.3.2 Characteristics .. 9KS 12.3.3 Characteristics .. 11KS 12.3.4 Characteristics .. 14KS 12.4 WIRING DIAGRAMS 12.4.1 Control .. 7KS to .. 14KS 12.4.2 Load .. 7KS to .. 14KS 12.4.3 Terminal Diagram ..
  • Page 11: Appendix: 12.1 Dimensioned Drawing

    APPENDIX: 12.1 DIMENSIONED DRAWING 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder Dimensioned Drawing...
  • Page 12: Appendix 10

    Abbreviations have the following meaning, e.g. B10 / W55: heat source temperature 10 °C and heating water supply temperature 55 °C. The heating circulating pump and the controller of the heat pump must be ready for operation at all times. s. EC Declaration of Conformity Please keep in mind that more space is required for pipe connection, operation and maintenanc.
  • Page 13 12.3.1 Characteristics .. 7KS Heating capacity in [kW] Conditions: Heating water flow rate 0,6 m³/h Brine flow rate 1,7 m³/h Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] Pressure loss in [Pa] 40000...
  • Page 14 APPENDIX: 12.3 SCHEMATICS 12.3.2 Characteristics .. 9KS Heating capacity in [kW] Conditions: Heating water flow rate 0,75 m³/h Brine flow rate Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] 2,3 m³/h 50000...
  • Page 15 12.3.3 Characteristics .. 11KS Heating capacity in [kW] Conditions: Heating water flow rate 1,0 m³/h Brine flow rate Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] 3,0 m³/h 40000 30000...
  • Page 16 APPENDIX: 12.3 SCHEMATICS 12.3.4 Characteristics .. 14KS Heating capacity in [kW] Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] Conditions: Heating water flow rate Brine flow rate Pressure loss in [Pa] 40000...
  • Page 17: Appendix: 12.4 Wiring Diagrams

    APPENDIX: 12.4 WIRING DIAGRAMS 12.4.1 Control .. 7KS to .. 14KS...
  • Page 18 APPENDIX: 12.4 WIRING DIAGRAMS 12.4.2 Load .. 7KS to .. 14KS...
  • Page 19 APPENDIX: 12.4 WIRING DIAGRAMS 12.4.3 Terminal Diagram .. 7KS to .. 14KS...
  • Page 20 M18* Hot water circulating pump M19* Swimming pool water circulating pump M21* Mixer, primary circuit M22* Mixer, heating circuit 2 Heat pump controller Soft starter N10* Remote control station N11* Relay module External sensor Return sensor Hot water sensor (as an alternative to the hot water thermostat)
  • Page 21: Appendix: 12.5 Hydraulic Block Diagram

    APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Hydraulic Block Diagram...
  • Page 22: Ec Declaration Of Conformity

    APPENDIX: 12.6 EC DECLARATION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmbach hereby confirm that the design and construction of the product(s) listed below, in the version(s) placed on the market by us, conform to the relevant requirements of the applicable EC directives.
  • Page 23 Notes...
  • Page 24 Glen Dimplex Deutschland GmbH Subject to technical modifications Division Dimplex Fax +49 92 21/709-589 Am Goldenen Feld 18 www.dimplex.de D-95326 Kulmbach...

This manual is also suitable for:

Si 7ksSi 9ksSi 11ksSi 14ks