INSTALLATION and OPERATING INSTRUCTIONS Brine-to-Water Heat Pump for Indoor Installation SI 7KS SI 9KS Order No.: 452231.67.01 SI 11KS SI 14KS FD 8504...
CONTENTS PLEASE READ IMMEDIATELY Important Information Legal Provisions and Directives Energy-Efficient Use of the Heat Pump PURPOSE OF THE HEAT PUMP Application Principle of Operation BASELINE UNIT ACCESSORIES Brine Manifold Brine Pressostat TRANSPORT INSTALLATION General Information Sound Emissions MOUNTING General...
VDE, EN and IEC standards. Beyond that, the connection requirements of the local utility compa- nies have to be observed. The heat pump is to be connected to the heat source and heat distribution systems in accordance with all applicable provisions.
A circulating pump then conveys the warmed brine to the evaporator of the heat pump. There, the heat is given off to the refrigerant in the refrigeration cycle. When so doing, the brine cools so that it can again take up heat energy in the brine circuit.
4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes.
Provided the controller and the heating circulating pumps are ready for operation, the frost protection function of the controller is always activated. If the heat pump is taken out of service or in the event of a power failure, the system must be drained. In heat...
Connection of the control voltage wire to the control panel of the heat pump. All electrical components required for the operation of the heat pump are located on the control panel.. For detailed instructions concerning the connection of external components and the operation of the heat pump controller refer to the heat pump terminal dia- gram and the operating manual of the controller.
- Drainage of the liquid emerging from the brine and heating water overflow valves must be ensured. 8.3 Commissioning Procedure The start-up of the heat pump is effected via the heat pump controller. CAUTION! Commissioning of the heat pump must be carried out in accordance with the installation and operating manual of the heat pump controller.
9.3 Cleaning of Heat Source Side CAUTION! The supplied strainer is to be install- ed in the heat source inlet of the heat pump in order to protect the evaporator against conta- mination. The filter screen of the strainer should be cleaned one day after commissioning, thereafter every week.
Abbreviations have the following meaning, e.g. B10 / W55: heat source temperature 10 °C and heating water supply temperature 55 °C. The heating circulating pump and the controller of the heat pump must be ready for operation at all times. s. EC Declaration of Conformity Please keep in mind that more space is required for pipe connection, operation and maintenanc.
Page 13
12.3.1 Characteristics .. 7KS Heating capacity in [kW] Conditions: Heating water flow rate 0,6 m³/h Brine flow rate 1,7 m³/h Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] Pressure loss in [Pa] 40000...
Page 14
APPENDIX: 12.3 SCHEMATICS 12.3.2 Characteristics .. 9KS Heating capacity in [kW] Conditions: Heating water flow rate 0,75 m³/h Brine flow rate Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] 2,3 m³/h 50000...
Page 15
12.3.3 Characteristics .. 11KS Heating capacity in [kW] Conditions: Heating water flow rate 1,0 m³/h Brine flow rate Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] 3,0 m³/h 40000 30000...
Page 16
APPENDIX: 12.3 SCHEMATICS 12.3.4 Characteristics .. 14KS Heating capacity in [kW] Power consumption (incl. power input to pump) Brine inlet temperature in [°C] Coefficient of performance (incl. power input to pump) Brine inlet temperature in [°C] Conditions: Heating water flow rate Brine flow rate Pressure loss in [Pa] 40000...
Page 20
M18* Hot water circulating pump M19* Swimming pool water circulating pump M21* Mixer, primary circuit M22* Mixer, heating circuit 2 Heat pump controller Soft starter N10* Remote control station N11* Relay module External sensor Return sensor Hot water sensor (as an alternative to the hot water thermostat)
APPENDIX: 12.6 EC DECLARATION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmbach hereby confirm that the design and construction of the product(s) listed below, in the version(s) placed on the market by us, conform to the relevant requirements of the applicable EC directives.