PID TEMPERATURE AND
PROCESS CONTROLLER
T2000P SERIES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T2000P Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CARLO GAVAZZI T2000P Series

  • Page 1 CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s PID TEMPERATURE AND PROCESS CONTROLLER T2000P SERIES...
  • Page 2: Instrument Panel Features

    Typical application Input options (diagrams) try again. Output options (diagrams) CARLO GAVAZZI When in program mode, after 60 seconds of key inactivity the display will revert to INPUT SENSOR SELECTION Temperature sensors either inPt : nonE or, if the initial configuration has been completed, the measured Linear input value.
  • Page 3: Functions Menu

    LEVL 4 DER.S DI.SS NO.AL PROG LOCK SET.L USER- PROTE CT E D S E TT I N GS CARLO GAVAZZI LEVL 3 SP1.D SP2.D BURN REU.D REU.L SPAN ZERO CHEK READ TECH UER RSET...
  • Page 4: Getting Started

    DAC overshoot inhibit feature. Care should be taken to ensure that any overshoot is safe Select SP1 (Main setpoint output device) for the process. CARLO GAVAZZI Analog output The Tune at Setpoint program is recommended when: The allocation of the analog output to SP1 automatically overrides the default The process is already at setpoint and control is poor proportional cycle time setting of 20 seconds.
  • Page 5: Proportional Cycle-Time

    ) and from the display tunE : oFF press and hold and press individually triggered when the process value changes according to the options listed CARLO GAVAZZI display tunE : on or tunE : At.SP Exit program mode ( below.
  • Page 6: Linear Input

    Action: Change the conditions. eg. raise setpoint Now configure Levels 1, 2 and 3 and if required proceed with AUTOTUNE. CARLO GAVAZZI Try tunE : At.SP Note: Any apparent calibration errors can be removed using the ZEro and SPAn adjustments in Level 3.
  • Page 7 * Deviation Alarms DV.hi, DV.Lo, bAnd 25% sensor maximum. LEVL 1 * Full scale alarms FS.hi, FS.Lo sensor range f/s [Factory settings] shown in brackets Function Options CARLO GAVAZZI SELECT AUTOTUNE (see pages 4/5) bnd.2 0.1 - * °C/°F/units [2.0 °C/3.6°F 2 units]...
  • Page 8: Output Configuration

    1d.2d to invert SP1 output T2016P2SRR SP1 Setpoint midscale burn Sensor burn-out/break protection T2016P2SSR RL Y Caution: Settings affect fail safe state. AnLG *T2016P2XRR CARLO GAVAZZI AnLG [uP.SC] Upscale Upscale dn.SC Downscale Downscale *T2016P2XSR AnLG 1u.2d Upscale Downscale AnLG 1d.2u...
  • Page 9 Enter level 4 at Lock , release together. Display reads LoCK nonE [1r.2d] Reverse Direct Program security using Lock [nonE] 1d.2d Direct Direct CARLO GAVAZZI Select from three Lock options: Press and hold , press to index. 1r.2r Reverse Reverse 1d.2r Direct Reverse LEV.3...
  • Page 10 SP3 SETTINGS SP3.A [nonE] dV.hi dV.lo bAnd FS.hi FS.Lo EoP Main SP3 operating mode SP3.b [nonE] LtCh hoLd Lt.ho Subsidiary SP3 operating mode CARLO GAVAZZI SEt.3 0 to 2500 SP3 setpoint adjustment hyS.3 0.1 to 100% of hiSC [20] Set SP3 hysteresis...
  • Page 11: Function Overview

    Display indicates progress through the sequence of segments, and can additionally be interrogated for further segment information. Program run mode CARLO GAVAZZI To speed up Program configuration, several Edit functions have been provided so that Display functions...
  • Page 12: Getting Started (Programmer)

    Upper display reads t.SP adjust the various FUNCTIONS as they appear in the FUNCTIONS MAP illustrated on pages 14 Lower display shows moving Ramp setpoint CARLO GAVAZZI and 15. Or if in Soak Segment Upper display reads Sint (Soak interval)
  • Page 13: Example Program

    EXAMPLE PROGRAM TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE SOAK STEP LOOP SOAK STEP Temp CARLO GAVAZZI SPRR SINT T.SP SPRR PCYC SPRR SINT T.SP SPRR T.SP T.SP T.SP T.SP Soak Function Interval: 45 mins Ramp Function Rate, 105 deg/hour...
  • Page 14: Programmer Function Map

    LEVEL C ‘off’ state beginning appears between LEVL PROG FAIL ST.V SPRU LEVEL P and LEVEL A CARLO GAVAZZI RSET HOUR Select the required LEVL program number. Default: 1 Select program mode Power failure recovery Select the starting point of...
  • Page 15 2D3E SP2 & SP3. Insert new New segment now EDIT E.OP segment in inserted into 2. Old CARLO GAVAZZI the menu 3 secs segment 2 becomes 3 2E3E SURE Segment 3 Delete a EDIT SURE E.OP...
  • Page 16 Delete segment † Edit inS Insert new segment † CARLO GAVAZZI † See examples of EDIT procedures (page 18) Deleting a Program automatically re-numbers those programs with higher numbers Until memory full. See page 11 for further explanation and memory allocation table...
  • Page 17 Ramp 4 Bytes an output for the full duration of Ramp with Holdback 5 Bytes that segment. Setting blocked CARLO GAVAZZI unless either or both outputs SP2A Soak 2 Bytes or SP3A have been configured as Step 3 Bytes an Event Output in Level 2 or Loops (1–3)
  • Page 18: Programming Examples

    Program Segment Configuration PROG See Program 3 illustrated on page 13 TYPE PCYC LOOP TYPE SPRR T.SP TYPE T.SP STEP CARLO GAVAZZI TYPE SINT SOAK Program settings for functions: PROG TYPE SPRR T.SP HB.V E.OP run; FAiL; St.U and SPru...
  • Page 19: Mechanical Installation

    Three types of output device may be factory fitted to the controllers, and users must choose the mounting instructions are carefully followed. CARLO GAVAZZI how to allocate these to outputs SP1 and SP2. (SP3 is always RLY). Check the model number...
  • Page 20: Typical Application

    SP1 to drive an SCR power controller providing a phase angle controlled output to Transducer the heater. F1 Fuse: 1A time lag type to IEC127. CSA/UL rating 250Vac F2 Fuse: High Rupture Capacity (HRC) Suitable for maximum rated load current Mains S1 Switch: IEC/CSA/UL Approved disconnecting device. CARLO GAVAZZI...
  • Page 21: Input Options

    T 2 0 1 6 P 2 R R R X – – X X 17 18 21 22 23 24 CARLO GAVAZZI Thermocouple (–) T 2 0 1 6 P 2 S R R X – – X X...
  • Page 22: Specification

    +/- 0.1% -199 to 9999 Keypad: 3 elastomeric buttons Environmental SPECIFICATION Humidity: Max 95% (non condensing) Altitude: up to 2000M CARLO GAVAZZI Installation: Categories ll and lll Thermocouple Pollution: Degree ll 9 types Protection: NEMA 4X, lP66 (Front panel only) Standards:...
  • Page 23: Safety And Warranty Information

    3 Components which wear, or damage with misuse, are excluded e.g. relays. 4 CARLO GAVAZZI shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product.
  • Page 24 Over a Twisted Pair • Up to 6 Miles (10km) Solid State Relays Switch It Send It CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s 750 Hastings Lane, Buffalo Grove, IL 60089 Phone 847.465.6100 Fax 847.465.7373...