ENLZS8WS_1G_PIVOT
Enhanced
INSTALLATION & USE MANUAL
LZ
Series Bottle Filling Stations & Coolers
Patent zurn-elkay.com/patents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
Page 1
2000002526 (Rev. A - 05/25)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ENLZS8WS 1G PIVOT and is the answer not in the manual?

Questions and answers

Summary of Contents for Elkay ENLZS8WS 1G PIVOT

  • Page 1 Enhanced INSTALLATION & USE MANUAL Series Bottle Filling Stations & Coolers ™ Patent zurn-elkay.com/patents WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Page 1...
  • Page 2 ENLZS8WS_1G_PIVOT Fig. 1 2000002526 (Rev. A - 05/25) Page 2...
  • Page 3 ENLZS8WS_1G_PIVOT INSTRUCTIONS FOR REMOVING WRAPPER Fig. B(ii) Fig. B(i) 1) Remove the two security screws (size T25) from the front panel. (see Fig B(i)) NOTE: SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY. 2) Gently pull the wrapper down and rotate the wrapper to a downward position (see Fig B(ii)).
  • Page 4 7) Connect electrical power by plugging in unit’s power cord. 8) Turn on water supply and flush filter to purge air and fine carbon particles from filter before use. Visit elkay.com/filtration for additional details. Also run water through bottle filler until all air is removed and water flow is clear.
  • Page 5 ENLZS8WS_1G_PIVOT FIG. 2 FIG. 3 Secure cooler frame to wall by installing (2) screws and washers (not supplied). Fig. 4 Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin. Fig. 5 Attach the 3/8" water line into the bulkhead fitting. Page 5 2000002526 (Rev.
  • Page 6 ENLZS8WS_1G_PIVOT Fig. 6 Fig. 7 Connect the bottle filler electrical harness. MOUNTING BOLT HOLES (6) WALL MOUNTING PLATE Fig. 8 BOTTLE FILLING UNIT 2000002526 (Rev. A - 05/25) Page 6...
  • Page 7 ENLZS8WS_1G_PIVOT 115V Refrigerated Wiring Diagram with Alpha/Numeric Display LZS8WSSP LZS8WSLP Fig. 9 WARNING • INGESTION HAZARD: This product contains a button cell or coin battery. • DEATH or serious injury can occur if ingested. • A swallowed button cell or coin battery can cause Internal Chemical Burns in as little as 2 hours.
  • Page 8 Do Not Overtighten. 3/8” Water Inlet 1 or 2 Scan for trouble shooting and to sign up for or 3 auto replenishment of authentic Elkay filters. Fig. 13 WATERSENTRY Filter Detail ® WATERSENTRY FILTER PARTS LIST ®...
  • Page 9 ENLZS8WS_1G_PIVOT Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, Remove two (2) screws from front of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 10 ENLZS8WS_1G_PIVOT 2000002526 (Rev. A - 05/25) Page 10...
  • Page 11 ENLZS8WS_1G_PIVOT Enhanced EZH2O Error Codes Error Error Description Corrective Action Code Bottle filler area obstructed • Remove obstruction. • Clean lens on IR sensor • Unplug unit for at least 30 seconds and restart • If error repeats, replace IR sensor E013 Missing or Incompatible Filter •...
  • Page 12 ENLZS8WS_1G_PIVOT Pictured is unit only without bottle filler. Note: Danger! Electrical shock hazard. Disconnect power before serviceing unit. Uses HFC-134A refrigerant Filter Location See Fig. 12 12 or 13 See Fig. 14 21, 24 Fig. 15 2000002526 (Rev. A - 05/25) Page 12...
  • Page 13 115V PARTS LIST ATTENTION: If the product serial number is before 190424189, please refer to archived PART ITEM DESCRIPTION documents section of Elkay.com for the most accurate parts list. (www.elkay.com/archived-documents) Hanger Bracket 28401C 0000001337 Basin - Stainless Steel Wiring - Front/Side Push Bar...
  • Page 14 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. • ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 • 630.574.8484 www.elkay.com 2000002526 (Rev. A - 05/25) Page 14...