1.3

SPECIFICATIONS

Dimensions:
Weight:
Pressure Supply
Pressure Range:
Supply Flow Rates:
Pressure
Connections:
Nominal Booster
Piston Ratio:
PGC-10000-AF SYSTEM
Temperature:
Relative Humidity:
© 2007 DH Instruments, a Fluke Company
GB-152 Booster:
584 mm H x 241 mm W x 241 mm D (23 in. x 9.5 in. x 9.5 in.)
GB-152 Booster:
16.4 kg (36 lbs)
Drive Air Control Kit:
1.8 kg (4 lbs)
Shop Drive Air:
75 psi (500 kPa)
Maximum high pressure output is drive air pressure
times 152
High Pressure Supply
400 to 3 000 psi (3 to 20 MPa)
Gas:
Maximum high pressure output is high pressure supply
times 25
Shop Drive Air:
15 to 75 scfm (425 to 2 125 slm)
High Pressure Supply
5 to 20 scfm (140 to 560 slm)
Gas:
Drive Air Supply Inlet:
1/4 in. NPT female
High Pressure Gas
Supply Inlet:
1/4 in. NPT female
High Pressure Outlet:
DH 500 female (DH500 F is a gland and collar type fitting for
coned and left hand threaded 1/4 in. (6 mm) OD tube,
equivalent to AE F250C, HIP HF4, etc.)
GB-152 Booster:
152:1
18 to 28 °C
Operating:
-20 to 70 °C
Storage:
Operating:
15 to 70%RH (non-condensing)
Storage:
10 to 90%RH (non-condensing)