Page 2
So that you can fully enjoy the services provided by Only a qualified HRLD200 repair technician should attempt to repair or Hanwei, while avoiding the misuse of your machine and the damage to the machine or other accident. Hanwei will not be responsible for the adjust the detector.
Page 3
Remark: Please contact the seller if the above troubleshooting Copyright Notice could not solve your problems The copyright of this manual belongs to Hanwei Electronics Group Corporation. Without written permission, any part of this manual may not 10. User’s Notes be copied, translated, stored in the database or retrieval system, nor may it The visible green Spotter beam is a Class 3R laser product.
Page 4
Do not expose detector to environment of electric shock, strong Dirty optical lens Clean the lens electromagnetic field or continuous severe vibrations. Charge the battery with the charger supplied by Hanwei. Reboot detector Do not charge in dangerous environment, please charge indoors in the Calibrate the wavelength...
Page 5
In order to maintain the HRLD200 in good working condition, the following industry or any place that is possible to have gas leakage.
Page 6
Display Color LCD Lifespan 10 years HRLD200 can detect leaks from up to 20 meters. Actual distance may vary Alarming method Visual and audible alarm due to target surface and environmental conditions. As the scanning An object that can be penetrated by light distance is increased, the laser light level returned will decrease.
Page 7
(2) The Detecting beam beam must pass through the pass through 4. Product introduction the gas mass. HRLD200 adopts the optical path design of transmitter-receiver integration, (3) The background target (i.e., ground, building, etc.) has to reflect which is easy to use. The detector emits two beams: detecting beam and the laser beam back, and the reflection rate shall be not less than aiming beam.
Page 8
Make sure there is enough residual power in the battery. Calibration over time will be displayed if the gas chamber is not When the laser from HRLD200 hits at the target gas pipeline, part of the installed before calibration. Contact the manufacture if the message is still beam will be absorbed if there has gas leakage.
Page 9
2 m 250ppm appears in the path between the be solved, please contact the manufacturer or the seller for solution. HRLD200 and the working beam of the background reflector is equal to Warning that of 100ppm * 5m =250ppm * 2m * = 500ppm·m.
Page 10
6.10 Device information When the detector is in standby interface, double press “>” button to view device information, such as device number, Bluetooth and software version information, etc. 6.11 Transmit When the detector is in standby interface, press “<” button, a transmit setting will pop up.
Page 11
6.1.2 Charging Charge the battery pack before the first time use of the detector. Power off the detector and start charging. Red LED indicates the charging is in progress. Unlit charging LED means anomaly. Green LED indicates the charging is complete and the charger can be disconnected. The charger is only applicable to this instrument.
Page 12
power button. The detector powers on and enters the standby state. give audible and visual alarm. The display will show real-time gas Double-pressing the power button and the detector enters the detection concentration as illustration of following picture. In this interface, if power state for measurement.
Need help?
Do you have a question about the HRLD200 and is the answer not in the manual?
Questions and answers