Evco S.r.l. • Code 104K411M0A02
EVK411M
Evco S.r.l. • Code 104K411M0A02
EVK411M
GB ENGLISH
GB ENGLISH
1
GETTING STARTED
1
GETTING STARTED
1 . 1 I m p o r t a n t
Read these instructions carefully before installing and using the instru-
ment and follow all additional information for installation and electrical
1 . 1 I m p o r t a n t
connection; keep these instructions close to the instrument for future
consultations.
Read these instructions carefully before installing and using the instru-
1 . 2 Installing the instrument
Panel mounting, with click brackets (supplied by the builder); dimen-
ment and follow all additional information for installation and electrical
sions in mm (in).
connection; keep these instructions close to the instrument for future
consultations.
1 . 2 Installing the instrument
Panel mounting, with click brackets (supplied by the builder); dimen-
sions in mm (in).
DIMENS.
MINIMUM
A
71.0 (2.795)
B
29.0 (1.141)
Additional information for installation:
• 59.0 (2.322) is the maximum depth with screw terminal blocks
• 83.0 (3.267) is the maximum depth with extractable terminal blocks
• the panel thickness must not be higher than 8.0 mm (0.314 in)
• working conditions (working temperature, humidity, etc.) must be be-
tween the limits indicated in the technical data
• do not install the instrument close to heating sources (heaters, hot air
ducts, etc.), devices provided with big magnetos (big speakers, etc.),
locations subject to direct sunlight, rain, humidity, dust, mechanical
vibrations or bumps
• according to the safety legislation, the protection against electrical
parts must be ensured by a correct installation of the instrument; the
parts that ensure the protection must be installed so that you can not
remove them if not by using a tool.
DIMENS.
1 . 3 Wiring diagram
With reference to the wiring diagram:
A
• terminals 4 and 5 are available only in the models with power supply
230 VAC and 115 VAC; terminals 6 and 7 are available only in the
B
models with power supply 12 VAC/DC and 12-24 VAC/DC
• the serial port (by request) is the port for the communication with the
supervision system (through a serial interface, via TTL, with MODBUS
communication protocol) or with the programming key; the port must
not be used at the same time for the same purposes.
Additional information for installation:
• 59.0 (2.322) is the maximum depth with screw terminal blocks
• 83.0 (3.267) is the maximum depth with extractable terminal blocks
• the panel thickness must not be higher than 8.0 mm (0.314 in)
Additional information for electrical connection:
• do not operate on the terminal blocks with electrical or pneumatic
• working conditions (working temperature, humidity, etc.) must be be-
screwers
• if the instrument has been moved from a cold location to a warm one,
tween the limits indicated in the technical data
the humidity could condense on the inside; wait about an hour be-
fore supplying it
• do not install the instrument close to heating sources (heaters, hot air
ducts, etc.), devices provided with big magnetos (big speakers, etc.),
locations subject to direct sunlight, rain, humidity, dust, mechanical
vibrations or bumps
• according to the safety legislation, the protection against electrical
parts must be ensured by a correct installation of the instrument; the
parts that ensure the protection must be installed so that you can not
remove them if not by using a tool.
1 . 3 Wiring diagram
With reference to the wiring diagram:
• terminals 4 and 5 are available only in the models with power supply
230 VAC and 115 VAC; terminals 6 and 7 are available only in the
models with power supply 12 VAC/DC and 12-24 VAC/DC
• the serial port (by request) is the port for the communication with the
supervision system (through a serial interface, via TTL, with MODBUS
communication protocol) or with the programming key; the port must
not be used at the same time for the same purposes.
Additional information for electrical connection:
• do not operate on the terminal blocks with electrical or pneumatic
screwers
• if the instrument has been moved from a cold location to a warm one,
the humidity could condense on the inside; wait about an hour be-
fore supplying it
Single output digital thermoregulator for general purposes
TYPICAL
MAXIMUM
71.0 (2.795)
71.8 (2.826)
29.0 (1.141)
29.8 (1.173)
MINIMUM
71.0 (2.795)
29.0 (1.141)
Single output digita
• test the working power supply voltage, working electrical frequency
and working electrical power of the instrument; they must correspond
with the local power supply
• disconnect the local power supply before servicing the instrument
• provide the thermocouple with a protection able to protect it against
contacts with metal parts or use insulated thermocouples
• do not use the instrument as safety device
• for repairs and information on the instrument please contact Evco
sales network.
2
USER INTERFACE
2 . 1 Turning on/off the instrument
To turn on the instrument you have to supply it; to turn it off it is enough
to cut off the power supply.
2 . 2 The display
If the instrument is turned on, during the normal operation the display
will show the quantity you have set with parameter P5:
• if P5 = 0, the display will show the room temperature
• if P5 = 1, the display will show the working setpoint.
2 . 3 Showing the room temperature
• make sure the keyboard is not locked and no procedure is running
• press
2 s: the display will show " Pb1"
• press
To quit the procedure:
• press
or do not operate 60 s
• press
or
as long as the display shows the quantity you have
set with parameter P5 or do not operate 60 s.
2 . 4 Activating the defrost by hand
• make sure the keyboard is not locked and no procedure is running
• press
4 s.
If parameter r5 has value 1 (heating action), the defrost functions will
not be enabled.
2 . 5 Locking/unlocking the keyboard
To lock the keyboard:
• make sure no procedure is running
• press
and
2 s: the display will show " Loc" 1 s.
If the keyboard is locked, you will not be allowed to:
• activate the defrost by hand
• modify the working setpoint with the procedure related in paragraph
4.1 (you also can modify the working setpoint through parameter SP).
These operations provoke the visualization of the label " Loc" 1 s.
To unlock the keyboard:
• press
and
2 s: the display will show " UnL" 1 s.
2 . 6 Silencing the buzzer
• make sure no procedure is running
• press a button (the first pressure of the button does not provoke its
usual effect).
3
OPERATION
3 . 1 Preliminary information
The operation mainly depends on parameter r5.
3 . 2 Operation with parameter r5 = 0 (cooling action)
TYPICAL
71.0 (2.795)
29.0 (1.141)
3 . 3 Operation with parameter r5 = 1 (heating action)
4
SETTINGS
4 . 1 Setting the working setpoint
• make sure the keyboard is not locked and no procedure is running
• press
LED out 1 will flash
• press
or
in 15 s; also look at parameters r1, r2 and r3
• press
or do not operate 15 s.
You also can modify the working setpoint through parameter SP.
4 . 2 Setting configuration parameters
To gain access the procedure:
• make sure no procedure is running
• press
and
4 s: the display will show " P A "
• press
• press
or
in 15 s to set " -19"
• press
or do not operate 15 s
• press
and
4 s: the display will show " SP".
To select a parameter:
• press
or
MAXIMUM
71.8 (2.826)
29.8 (1.173)
To m
• pres
• pres
• pres
To qu
• pres
Swit
mod
4 . 3
• ma
• pres
• pres
• pres
• pres
• pres
• pres
• pres
• pres
• swi
Make
ate,
5
5 . 1
LE
ou
°
°
CO
L
6
6 . 1
CO
AL
AL
When
ment
7
7 . 1
CO
P
When
ment
8
8 . 1
Box:
Fron
Conn
put),
block
Work
relati
Powe
12-24
Alarm
Meas
coup
and 0
Need help?
Do you have a question about the EVK411M and is the answer not in the manual?