instruction manual AXC-TEMP Temperature Control Card and RTS-1 Room Temperature Sensor A x c e s s C o n t r o l C a r d s...
Page 2
Consumers should inquire from selling dealer as to the nature and extent of the dealer’s warranty, if any. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform, including any lost profits, lost savings, incidental damages, or consequential damages.
Product Information Product Information The AXC-TEMP Temperature Control card (FIG. 1) provides control and power for the RTS1 Room Temperature Sensor (FIG. 2). The RTS1 provides precision temperature sensing for the AXT-TEMP. FIG. 1 AXC-TEMP FIG. 2 RTS1 Features The AXC-TEMP features include: Standard Axcess CardFrame slot size Settings for Fahrenheit or Celsius operation Control and power for up to four independent RTS1 units...
Page 6
Product Information The table below lists the specifications for the AXC-TEMP and RTS1. Specifications AXC-TEMP Input voltage +12 to 18 VDC Current Draw 40 mA (using four RTS1s = 75 mA) 0.0 ° F to +250 ° F (0.0 ° C to +106.9 ° C) Temperature range +/-2 °...
Pre-Installation Pre-Installation Before installing the AXT-TEMP and RTS1, you must properly set jumpers and potentiometers (POTs). Setting Fahrenheit or Celsius Set the Fahrenheit or Celsius feature by manually selecting each jumper (JP1- JP4) or by manually selecting the RAW A/D OUTPUT jumper on the card. FIG. 3 shows the location of the jumpers and POTs.
Pre-Installation 4. Hold the card by the tab end and slide the card into the frame. Make sure the card is correctly positioned in the guide slot. 5. Gently push the card in until it is firmly seated in the card connector slot. It is not necessary to disconnect the power to the CardFrame when installing the card.
Use Belden 8723 or equivalent cable. When an application or code requires plenum-rated cable, use Belden 88723 or equivalent cable. Call AMX Technical Support for any installations that require a wire run of more than 100 feet. RTS1 depth is 0.9"...
Pre-Installation AXC-TEMP Ground Black Black Ground RTS1 Unit 1 Drain Drain Green Green Axcess Input White White Output Belden 8723, CardFrame or equivalent Power Red Red Power (Twisted Pair) Ground Black Black Ground RTS1 Unit 2 Drain Drain Green Green Input White White Output Belden 8723,...
Pre-Installation Testing the RTS1 Touch the sensor at the bottom each RTS1 unit for a few seconds. The temperature on the display panel should change. If the temperature does not change: 1. Check the wiring to each RTS1 unit that did not display a temperature change. 2.
Page 12
Pre-Installation AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor...
Programming Programming This section provides the Axcess programming commands for the AXC-TEMP and RTS1. The TEMP_LEVEL variable receives data from the TEMP card (Device 16), inputs 1 - 4. The data is in three-digit numbers (986 = 98.6 degrees). The SEND_STRING command to the Mini-LCD Panel converts the number to print with a decimal point.
Page 14