INSTALLATION MANUAL 4.11 12/2024 For the aleo modules LEO (L62, L64) with standard frame 40 mm: LEO Black (L82, L84) LEO-N (L62, L64) LEO-N Black (L82, L84) LEO Sol (S82, S84) with frame for roof integration: LEO-N Sol (S82, S84)
Some countries specify a larger bend radius, e.g. 8-fold wire diameter in the USA (NEC Codebook 2011). For attaching cable clips, use a suitable tool which constrict or damage the cable insulation by tightening. aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | info@aleo-solar.com installation manual V 4.11, 12/2024, EN...
According to the standard IEC 61215, a photovoltaic module should have an insulation resistance of at least 40 MΩ/m2. Some inverters provide the measured insulation resistance via an interface. aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | info@aleo-solar.com installation manual V 4.11, 12/2024, EN...
Distilled or demineralised water is often used by cleaning services but can damage glass surfaces with frequent intensive use over long periods of time. aleo solar therefore advises against the use of distilled or demineralised water. Rainwater has a low level of water hardness. It is beneficial to use it because a build-up of deposits is avoided.