INSTALLATION
MANUAL
Jolywood N-type Mono-crystalline Double Glass Module
All rights reserved © Jolywood (Taizhou) Solar Technology Co., Ltd

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD156N and is the answer not in the manual?

Questions and answers

Summary of Contents for Jolywood HD156N

  • Page 1 INSTALLATION MANUAL Jolywood N-type Mono-crystalline Double Glass Module All rights reserved © Jolywood (Taizhou) Solar Technology Co., Ltd...
  • Page 2: Table Of Contents

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Contents Revision Date 2024/10/09 Version: TZ-MP-099-2024-V7 Introduction ������������������������� Declaration ������������������������� Limitation of Liability ��������������������� Safety Precautions ���������������������� Warning ��������������������������� General Safety ������������������������ Operation instruction ��������������������� Unload, Transportation and Storage �������������� Marks on Outer Packaging �������������������...
  • Page 3: Introduction

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module The module installer must inform the end 1.0 Introduction customer (or consumer) of the above matters accordingly. This manual contains relevant information about the installation methods and safe operation of 1.1 Declaration photovoltaic modules (hereinafter referred to as "modules") of Jolywood Solar Technology Co., Ltd...
  • Page 4: General Safety

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module operation instruction 2.3.1 General Safety In order to avoid damage module, please do not 2.2.1 scratch or hit module, and do not use paint or It is strictly forbidden to use modules with broken glass.
  • Page 5: Marks On Outer Packaging

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module with recommended shipping method unpacking procedure. In order to avoid damage, scratch or strike module. Do not apply pressure directly on the module during transportation. Improper transportation or installation also may damage module, which is excluded from the warranty.
  • Page 6: Unloading Instructions

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module attached to the vehicle with ropes. Pallets are Unloading Instructions prohibited beyond the loading area of transport 3.2.1 When unloading modules from vehicle, less than vehicles. 2 lots package could be lifted each time with a reasonable fixture.
  • Page 7: Unpacking Instruction

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module the soft and collapsible ground. Instead, the hard 4.1.3 ground or the ground with high terrain should be Wear protective gloves during unpacking to avoid selected and leveled to ensure that the modules injury and fingerprints on the glass surface...
  • Page 8: Installation

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module the other side of package, and then carry them. If 5.1.2 unpacking on a non-horizontal floor, use a remove module package before supportive tool to ensure package placed installation. verticality. 5.1.3 When installing modules, only work in a dry 4.2.4...
  • Page 9: Installation Method

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 5.1.8 5.2.2 Framed Bifacial Double-Glass After modules are installed, the cables should be Modules (installation with clamps) fixed or tied to avoid exposed under direct Clamp: sunlight after installation, which would prevent cable from aging.
  • Page 10 Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Press block installation mode and corresponding static load: Four point long side installation of mounting rail Four point long side installation of mounting rail perpendicular to the long side parallel to the long side...
  • Page 11: Framed Bifacial Double-Glass Modules (Installation With Bolt)

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Four point short edge Installation Four point long side Four point long edge Four point short side Four point short side installation+two point installation of nstallation of installation of Four point...
  • Page 12 Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Bolt installation method and corresponding static load: Long frame with inner four holes Long frame with inner four holes mounting rail parallel to the long side mounting rail perpendicular to the long side (HD108N(M10)&HD108N-R0 &...
  • Page 13: Installation Of Full Frame Double Glass Modules

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Long frame with Long frame with Long frame with Long frame with Long frame with Long frame with Long frame with Long frame with Instllation inner four holes 400mm&1400mm inner four holes...
  • Page 14: Grounding

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Installation The flat single shaft is The flat single shaft is The flat single shaft is The flat single shaft is installed with 400mm installed with 1100mm mounted with 1300mm installed with 1400mm...
  • Page 15: Electrical Installation

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 5.2.6 Electrical Installation Under certain conditions, a module may produce All wiring should be performed by a qualified and more current or voltage than its Standard Test trained person accordance with local Conditions rated power.
  • Page 16: Wiring

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Alternatively, a more accurate correction factor for series or in parallel needs to be reasonably the open-circuit voltage can be calculated using designed according to the system configuration. the following formula: All instructions above must be followed to meet α...
  • Page 17: Maintenance For Pv Modules

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 6.1.5 6.Maintenance for PV Modules Cover the front surface of Modules with an opaque material. Modules exposed under the sun could 6.1.Module Visual Inspection and be extremely dangerous, as high voltages could...
  • Page 18: Cleaning

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module f)If you are not sure whether the array need to 6.3.Cleaning cleaned, first select a column of particularly dirty The amount of electricity produced by a solar array to begin cleaning. If the power generated...
  • Page 19: Module Inspection After Cleaning

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 7. Technical Issues or Claims 6.3.2 Module inspection after cleaning 6.3.2.1 If you have any questions about technology or The overall appearance of modules is clean, claims, please contact the installer.