1. BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
■ Do not install the unit by yourself (user).
■ Perform the installation securely referring to the
installation manual.
■ When installing the unit, use appropriate protective
equipment and tools for safety.
■ Install the unit securely in a place which can bear
the weight of the unit.
■ Do not alter the unit.
experienced electrician, according to the installation
manual. Be sure to use an exclusive circuit. Do not
connect other electrical appliances to the circuit.
■ Earth the unit correctly.
■ Do not damage the wires by applying excessive
pressure with parts or screws.
■ Be sure to cut off the main power in case of setting
up the indoor P.C. board or wiring works.
the terminal block connecting sections so the stress
of the wires is not applied to the sections. Do not
extend the wires, or use intermediate connection.
gas may leak.
■ Do not use intermediate connection of the power
cord or the extension cord and do not connect many
devices to one AC outlet.
for the installation work.
■ Install an earth leakage breaker depending on the
installation place.
■ Perform the drainage/piping work securely ac-
cording to the installation manual.
REFRIGERANT
Model names are indicated in 1-3.
®
WARNING
■ When plugging the power supply plug into the
outlet, make sure that there is no dust, clogging,
or loose parts in both the outlet and the plug. Make
sure that the power supply plug is pushed com-
pletely into the outlet.
■ Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.
■ When installing, relocating, or servicing the unit,
make sure that no substance other than the speci-
■ Do not discharge the refrigerant into the atmos-
phere. If refrigerant leaks during installation, ven-
tilate the room. Check that the refrigerant does not
leak after installation has been completed.
■ Use appropriate tools and piping materials for instal-
lation.
■ When pumping down the refrigerant, stop the com-
pressor before disconnecting the refrigerant pipes.
■ When installing the unit, securely connect the re-
frigerant pipes before starting the compressor.
in this manual.
CAUTION
the outdoor unit.
■ Do not install the outdoor unit where small animals
may live.
Required Tools for Installation
Scale
■ The unit shall be installed in accordance with na-
tional wiring regulations.
equipment, completely remove all of the refrigerant
from the air conditioner and ensure that the area is
well-ventilated.
■ Do not use means to accelerate the defrosting pro-
cess or to clean, other than those recommended by
the manufacturer.
■ The appliance shall be stored in a room without
continuously operating ignition sources (for exam-
operating electric heater).
■ Do not pierce or burn.
■ Be aware that refrigerants may not contain an odour.
■ Pipe-work shall be protected from physical damage.
■ The installation of pipe-work shall be kept to a
minimum.
■ Compliance with national gas regulations shall be
observed.
■ Keep any required ventilation openings clear of
obstruction.
For Wi-Fi
interface
®
■ Do not install the indoor unit equipped with the
Wi-Fi
interface nearby the automatic control de-
®
■ Do not use the indoor unit equipped with the Wi-Fi
interface nearby the medical electrical equipment
or people who have a medical device such as a
cardiac pacemaker or an implantable cardioverter-
■ This indoor unit equipped with the Wi-Fi
should be installed and operated with a minimum
distance of 20 cm between the device and the user
or bystanders.
■ Do not operate the air conditioner during interior
®
interface
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSZ-EF22 KS and is the answer not in the manual?

Questions and answers

Summarization of Contents

Before Installation
Meanings of Symbols on Units
Explains symbols used on indoor and outdoor units for safety and operation.
Safety Observations
Key safety precautions to be observed during installation and operation.
Installation Location Selection
Indoor Unit Location
Guidelines for choosing the optimal location for the indoor unit.
Outdoor Unit Location
Guidelines for choosing the optimal location for the outdoor unit.
Remote Controller Placement
Recommendations for placing the remote controller for best operation.
Installation Diagram
Included Accessories
Lists all accessories included with the indoor and outdoor units.
Site-Provided Parts
Lists parts that must be supplied at the installation site.
Outdoor Unit Installation Diagram
Diagram illustrating proper installation requirements for the outdoor unit.
Outdoor Unit Drain Piping Diagram
Instructions and diagram for setting up the outdoor unit's drain piping.
Important Installation Notes
Crucial notes regarding installation, wiring, and unit operation.
Indoor Unit Installation
Fixing the Installation Plate
Detailed steps for securely fixing the indoor unit's installation plate to the wall.
Wall Hole Drilling
Procedure for drilling the correct size hole through the wall for piping.
Connecting Indoor Unit Wires
Instructions for connecting the indoor and outdoor unit wiring to the indoor unit's terminal block.
Pipe Forming and Drain Piping
Pipe Forming and Taping
Steps for properly forming and taping refrigerant pipes and drain hoses.
Rear, Right, or Downward Piping
Instructions for routing pipes towards the rear, right, or downward.
Left or Left-Rear Piping
Instructions for routing pipes towards the left or left-rear.
Drain Piping Installation
Detailed procedures for installing the drain hose for proper water drainage.
Incorrect Drain Piping Methods
Illustrates incorrect drain piping methods to avoid.
Outdoor Unit Installation
Connecting Outdoor Unit Wires
Steps for connecting the power supply and indoor/outdoor unit wires to the outdoor unit.
Flaring Work Procedure
Guide on how to properly flare the ends of copper pipes for connection.
Refrigerant Pipe Connection
Instructions for connecting refrigerant pipes to the indoor and outdoor units using specific torque.
Pipe Insulation and Taping
Procedures for insulating and taping all refrigerant piping, especially near the outdoor unit.
Purging, Leak Test, and Test Run
Purging Procedures and Leak Test
Steps for removing air and moisture and testing for refrigerant leaks.
Test Run Procedure
Instructions for performing an initial test run of the air conditioner.
Remote Signal Reception Check
How to verify the indoor unit correctly receives signals from the remote controller.
Auto Restart Function
Explanation of the auto restart function and how to deactivate it.
User Explanation Guide
Guidance on explaining unit operation and features to the end-user.
Relocation and Maintenance
Panel Assembly Removal and Installation
Procedures for removing and reinstalling the front panel assembly of the indoor unit.
Indoor Unit Removal
Steps to detach the indoor unit from its installation plate.
Pumping Down Refrigerant
How to safely pump down the refrigerant before relocating or disposing of the unit.
Connecting Interface/Connector Cable
Instructions for connecting the interface/connector cable to the air conditioner's electronic control board.

Table of Contents