SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
1. BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
■ Do not install the unit by yourself (user).
■ Perform the installation securely referring to the
installation manual.
■ When installing the unit, use appropriate protective
equipment and tools for safety.
■ Install the unit securely in a place which can bear
the weight of the unit.
■ Do not alter the unit.
experienced electrician, according to the installation
manual. Be sure to use an exclusive circuit. Do not
connect other electrical appliances to the circuit.
■ Earth the unit correctly.
■ Do not damage the wires by applying excessive
pressure with parts or screws.
■ Be sure to cut off the main power in case of setting
up the indoor P.C. board or wiring works.
the terminal block connecting sections so the stress
of the wires is not applied to the sections. Do not
extend the wires, or use intermediate connection.
gas may leak.
■ Do not use intermediate connection of the power
cord or the extension cord and do not connect many
devices to one AC outlet.
for the installation work.
■ Install an earth leakage breaker depending on the
installation place.
■ Perform the drainage/piping work securely ac-
cording to the installation manual.
REFRIGERANT
Model names are indicated in 1-3.
®
WARNING
■ When plugging the power supply plug into the
outlet, make sure that there is no dust, clogging,
or loose parts in both the outlet and the plug. Make
sure that the power supply plug is pushed com-
pletely into the outlet.
■ Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.
■ When installing, relocating, or servicing the unit,
make sure that no substance other than the speci-
■ Do not discharge the refrigerant into the atmos-
phere. If refrigerant leaks during installation, ven-
tilate the room. Check that the refrigerant does not
leak after installation has been completed.
■ Use appropriate tools and piping materials for instal-
lation.
■ When pumping down the refrigerant, stop the com-
pressor before disconnecting the refrigerant pipes.
■ When installing the unit, securely connect the re-
frigerant pipes before starting the compressor.
in this manual.
CAUTION
the outdoor unit.
■ Do not install the outdoor unit where small animals
may live.
Required Tools for Installation
Scale
■ The unit shall be installed in accordance with na-
tional wiring regulations.
equipment, completely remove all of the refrigerant
from the air conditioner and ensure that the area is
well-ventilated.
■ Do not use means to accelerate the defrosting pro-
cess or to clean, other than those recommended by
the manufacturer.
■ The appliance shall be stored in a room without
continuously operating ignition sources (for exam-
operating electric heater).
■ Do not pierce or burn.
■ Be aware that refrigerants may not contain an odour.
■ Pipe-work shall be protected from physical damage.
■ The installation of pipe-work shall be kept to a
minimum.
■ Compliance with national gas regulations shall be
observed.
■ Keep any required ventilation openings clear of
obstruction.
For Wi-Fi
interface
®
■ Do not install the indoor unit equipped with the
Wi-Fi
interface nearby the automatic control de-
®
■ Do not use the indoor unit equipped with the Wi-Fi
interface nearby the medical electrical equipment
or people who have a medical device such as a
cardiac pacemaker or an implantable cardioverter-
■ This indoor unit equipped with the Wi-Fi
should be installed and operated with a minimum
distance of 20 cm between the device and the user
or bystanders.
■ Do not operate the air conditioner during interior
®
interface
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSZ-EF22 S and is the answer not in the manual?

Questions and answers

Summarization of Contents

Before Installation
Safety Symbols and Warnings
Describes symbols, hazards, and general safety precautions for unit operation.
Critical Safety Precautions
Details severe risks including death or serious injury from improper handling.
Cautionary Installation Advice
Provides warnings for potential injury in specific environments due to incorrect installation.
Installation Location Guidance
Indoor Unit Placement Criteria
Requirements for selecting the optimal location for the indoor unit.
Outdoor Unit Placement Criteria
Requirements for selecting the optimal location for the outdoor unit.
Remote Control Signal Location
Guidelines for ensuring proper remote controller signal reception.
Unit Technical Specifications
Model Specifications Overview
Details unit model, power supply, and pipe size requirements.
Installation Diagrams and Parts
Included Unit Accessories
Lists all parts provided with the air conditioner for installation.
Installer-Provided Components
Lists components required from the installation site.
Key Installation Notes
Important considerations and tips for a successful installation.
Indoor Unit Mounting and Wiring
Fixing the Installation Plate
Step-by-step guide for securely mounting the unit's installation plate.
Drilling the Wall Opening
Instructions for preparing the wall hole for piping and wiring.
Connecting Indoor Unit Wires
Detailed steps for electrical wiring of the indoor unit to the outdoor unit.
Pipe and Drain Setup
Shaping Refrigerant Pipes
Techniques for preparing refrigerant pipes for connection.
Installing the Drain Piping
Correct methods for setting up the condensate drain hose.
Drain Piping Avoidance
Visual guide to incorrect drain piping methods to prevent issues.
Outdoor Unit Installation and Connections
Outdoor Unit Electrical Wiring
Steps for connecting power and control wires to the outdoor unit.
Flaring Copper Pipework
Process for creating precise flares on refrigerant pipes.
Connecting Refrigerant Pipe Joints
How to securely connect pipework to unit valves using torque.
Insulating and Taping Pipework
Instructions for protecting and sealing pipe connections against condensation.
System Testing and User Handover
Purging, Leak Test, and Evacuation
Procedures for preparing the refrigerant system and checking for leaks.
Performing the Test Run
Guide for verifying unit operation and checking for errors after installation.
Understanding Auto Restart Function
Explanation of the automatic restart feature for power outages.
Explaining Unit Operation to User
Guidance on how to brief the end-user on unit features and operation.
Relocation, Maintenance, and Interface
Panel Assembly Management
Procedures for removing and reinstalling the unit's front panel assembly.
Removing the Indoor Unit
Steps for detaching the indoor unit from its wall mounting.
Refrigerant Pumping Down Procedure
Method to safely recover refrigerant before relocation or disposal.
Connecting Interface and Connector Cables
How to connect communication and interface cables for optional features.
Additional Resources
MUZ-EF25VG Model Document Links
Links to related manuals, product sheets, and declarations for the model.

Table of Contents