Download Print this page

Lode Excalibur Sport Manual

Ergometry manager multibike
Hide thumbs Also See for Excalibur Sport:

Advertisement

Quick Links

Lode Ergometer – Lode Ergometry Manager Multibike
STEP I
1. For controlling the first ergometer by the Lode Ergometry Manager you need a RS232
cable (part no. 930911 ), The lay-out of the cable is as follows:
D-con 9 pin female
2 RxD
---------------------------------------------------------------------------- 2 TxD
3 TxD
---------------------------------------------------------------------------- 3 RxD
5 GND
---------------------------------------------------------------------------- 5 GND
2. Connect the RS232 cable to the RS232 in port of the ergometer (see figure 1).
3. Connect the RS232 cable to the computer of the Lode Ergometry Manager (see figure 2).
4. For connecting a following ergometer to the computer with the Lode Ergometry Manager
Multibike software you can either connect it to a free COM port on the computer by using
the straight RS232 cable 930911 or connect the next ergometer to the previous ergometer
by using the RS232 cable ( part no. 928717) The layout of the cable is as follows:
D-con 9 pin male
2 RxD
---------------------------------------------------------------------------- 3 TxD
3 TxD
---------------------------------------------------------------------------- 2 RxD
5 GND
---------------------------------------------------------------------------- 5 GND
5. Connect the RS232 cable to the RS232 in port of the ergometer (see figure 1).
6. Connect the RS232 cable to the computer of the Lode Ergometry Manager (see figure 2)
or connect the RS232 cable to the RS232 out port of the previous ergometer (see figure 1)
STEP II
7. Switch on the ergometers
The Lode ergometers are default shipped with the LODE RS232 communication protocol.
It should be set to the "LODE prot 38K4" RS232 protocol.
You can change the RS232 by following the procedure below:
Switch on the ergometer and press enter.
You will be in the "MAINMENU"
Select, by using the up/down keys, the menu "SYSTEM PARAMETER" and press enter
Select, by using the up/down keys, the menu "SETTINGS" and press enter
INTERFACE
Setting up the hardware
Straight RS232 cable 930911
RS232 cable 928717
Setting up the ergometer
D-con 9 pin male
D-con 9 pin male

Advertisement

loading
Need help?

Need help?

Do you have a question about the Excalibur Sport and is the answer not in the manual?

Questions and answers

Summarization of Contents

Setting up the hardware
RS232 Cable for First Ergometer
Specifies the RS232 cable (part no. 930911) required for connecting the initial ergometer.
RS232 Cable for Subsequent Ergometers
Details the RS232 cable (part no. 928717) for connecting additional ergometers in a multi-bike setup.
Setting up the ergometer
Ergometer Protocol Configuration
Sets the default RS232 protocol to "LODE prot 38K4" and explains how to change it.
Unique Device Number Assignment
Ensures each ergometer has a unique device number for Multibike sessions.
Ergometer Terminal Mode Setup
Configures the ergometer to operate in "TERMINAL" mode for external control.
Setting up the Lode Ergometry Manager
LEM Software Login Procedure
Guides users to log into the LEM software using default credentials.
License Code Entry
Instructs on entering the correct license code obtained from the LEM CD.
Ergometer Configuration and Testing
Covers adding, editing, configuring, and testing ergometers within the LEM software.