2.3 LED Information
LEDs
D11
D32
D36
2.4 Fan Header Information
Fan #
Fan Description
1
CPU 2 fan
2
CPU 1 fan
3
Chassis fan 3
4
Chassis fan 4
5
Chassis fan 5
6
Chassis fan 6
7
Chassis fan 7
8
Chassis fan 8
9
Chassis fan 9
10
Chassis fan 10
11
Chassis fan 11
Description
CPU Voltage Mismatch (LED)
Red LED activates if single CPU is placed in CPU 2 socket. May also
activate if CPUs are mismatched – ie. Using two different Xeons. If
installing only one CPU, it must be placed in CPU 1. (Light will remain off
if CPUs are placed correctly.)
GbE
Green light activates if GbE is programmed correctly. Light stays on until
the OS finishes loading.
Power on LED
RPM Read and controlled
RPM Read and controlled
RPM Read and controlled
RPM Read
RPM Read
RPM Read
http://www.TYAN.com
Functions
None
None
None
None
None
11
Amp Rated
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
2A
2A
2A
2A
2A