SPECIFICATIONS
POWER SUPPLY REQUIREMENTS
MOTOR
HORSEPOWER
CIRCUIT REQUIREMENTS
DIMENSIONS
ON LEVEL (FACTORY SET)
OFF LEVEL (FACTORY SET)
CONSTRUCTION
MOTOR HOUSING
Stainless Steel
MOTOR SHAFT
Carbon Steel
IMPELLER
Dual Glass Reinforced Thermoplastic
VOLUTE
Cast Iron
PUMP DISCHARGE
1-1/2 in. NPT
PERFORMANCE (Gal/hr)
Discharge Head (Lift Distance)
Model
HP
0 ft
5 ft
1000RSDS
1
6360
5700
500RSDS
1/2
4980
4140
330RSDS
1/3
4440
3780
© 2023, RIDGID TOOL COMPANY
120 V, 60 Hz
Single Phase, Dielectric Oil Filled
1 HP ...............( 1000RSDS )
1/2 HP ............ (500RSDS)
1/3 HP ............ (330RSDS)
15 A (minimum)
12 in. high x 7-1/2in. base (ALL MODELS)
Approximately 9 in. (ALL MODELS)
Approximately 4 in. (ALL MODELS)
10 ft
15 ft
20 ft
4980
4140
3240
3240
2100
720
2940
1920
660
Intended for Indoor Use Only
Dual Suction Sump Pumps
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
www.homedepot.com
Dual Suction Series
600004W-005 D 11/23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 330RSDS and is the answer not in the manual?

Questions and answers

Summarization of Contents

PRODUCT SPECIFICATIONS AND PERFORMANCE
Technical Specifications
Details electrical, dimensional, operational levels, and construction materials of the pump.
Performance Data
Provides pump flow rates (Gal/hr) at various discharge head lift distances for different models.
IMPORTANT SAFETY INFORMATION
General Safety Warnings
Highlights potentially hazardous situations that could result in death or serious injury if not avoided.
Electrical Safety Requirements
Details mandatory electrical safety measures, including proper grounding, GFCI protection, and circuit breaker ratings.
OPERATING AND INSTALLATION SAFETY
Electrical and Fluid Handling Safety
Warns against electrical shock risks and prohibits pumping flammable fluids or drinking water.
Installation Safety Guidelines
Prohibits the use of extension cords and surge protectors due to potential safety hazards during installation.
INSTALLATION REQUIREMENTS AND GUIDELINES
Piping, Valve, and Handling Requirements
Mandates rigid piping, check valve, and proper lifting methods for installation and safe handling.
Damage and Alarm Precautions
Advises against using damaged pumps and suggests high water alarms for property protection.
TYPICAL SUMP INSTALLATION
Installation Steps and Best Practices
Outlines the step-by-step process for installing the sump pump, including basin preparation and connection.
TROUBLESHOOTING
Troubleshooting Safety Warnings
Provides critical safety warnings before attempting any troubleshooting or servicing of the pump.
Pump Operational Issues
Lists common pump operational problems and their potential causes and suggested remedies.
Pump Intermittent Operation
Addresses issues where the pump cycles unexpectedly due to thermal overload or other factors.
ADVANCED TROUBLESHOOTING AND MAINTENANCE
Specific Troubleshooting Scenarios
Details solutions for specific troubleshooting scenarios like GFCI trips or low/no water delivery.
Routine Maintenance Procedures
Explains the recommended inspection frequency and key maintenance checks for optimal pump performance.
WARRANTY AND SERVICE PARTS
Replacement Parts Identification
Identifies available replacement parts, specifically the float kit, with reference numbers and part numbers.
CUSTOMER SUPPORT AND LIMITED WARRANTY
Warranty Terms and Claims
Outlines the terms and conditions of the limited warranty, coverage, and how to make a claim.

Table of Contents