INSTALLATION
Continued
12"
10"
8"
6"
1 /2
2
"
Minimum Non-
Combustible
Material
8"
Min.
Hood
Hood (GA6050,
(GA6050, GA6052)
GA6052 or
GA6053)
Figure 7 - Minimum Mantel Clearances When Using Hood
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain
the minimum distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the combustible floor-
ing (see Figure 9).
Combustible
Material
14"
Min.
Noncombustible Material
Figure 8 - Minimum Fireplace
Clearances If Installed at Floor
Level
INSTALLING DAMPER CLAMP ACCESSORY
FOR VENTED OPERATION
Note: When used as a vented heater, appliance must be installed
only in a solid-fuel burning fireplace with a working flue and
constructed of noncombustible material.
If your heater is a manually controlled model, you may use this
heater as a vented product. There are three reasons for operating
your heater in the vented mode:
1. The fireplace does not meet the clearance to combustibles re-
quirements for vent-free operation
2. State or local codes do not permit vent-free operation
3. You prefer vented operation
111115-01D
Mantel Shelf
Underside of
Mantel Shelf
All minimum
distances are
in inches
12"
15"
18"
20"
Top of Fireplace
Opening
Distances to
Underside of
Mantel
Hearth
Combustible
Material
5"
Min.
Figure 9 - Minimum Fireplace
Clearances Above Combus-
tible Flooring
For more information, visit www.desatech.com
For more information, visit www.desatech.com

Installing Damper Clamp Accessory for Vented Operation

If reasons number 1 or 2 above apply to you, you must permanently
open chimney flue damper. You must install the damper clamp
accessory (to order, see Accessories, page 27). This will insure vented
operation (see Figure 10). The damper clamp will keep damper open.
Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must
provide. Attach damper clamp so the minimum permanent flue
opening will be maintained at all times.
Chimney Height (ft.) Minimum Permanent Flue Opening
6' to 15'
15' to 30'
Area of Various Standard Round Flues
Diameter (ins.)
Damper
Clamp
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
INSTALLATION
Mantel Clearances (Cont.)
Floor Clearances
39 sq. inches
29 sq. inches
Area (sq. ins.)
5"
20 sq. inches
6"
29 sq. inches
7"
39 sq. inches
8"
51 sq. inches
Damper
Damper
Clamp
Damper
Manufactured Fireplace
9 9