Download Print this page

Advertisement

Quick Links

Packaged Air-Conditioners
INDOOR UNIT
SFZ-M25, M35, M50, M60, M71VA
OPERATION MANUAL
BEDIENUNGSHANDBUCH
MANUEL D'UTILISATION
BEDIENINGSHANDLEIDING
MANUAL DE INSTRUCCIONES
ISTRUZIONI DI FUNZIONAMENTO
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ
MANUAL DE OPERAÇÃO
DRIFTSMANUAL
DRIFTSMANUAL
IŞLETME ELKİTABI
РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ
INSTRUKCJA OBSŁUGI
BRUKSANVISNING
KÄYTTÖOPAS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ПОСІБНИК З ЕКСПЛУАТАЦІЇ
PROVOZNÍ PŘÍRUČKA
NÁVOD NA OBSLUHU
HASZNÁLATI KÉZIKÖNYV
NAVODILA ZA UPORABO
MANUAL DE UTILIZARE
KASUTUSJUHEND
LIETOŠANAS ROKASGRĀMATA
NAUDOJIMO VADOVAS
PRIRUČNIK ZA RUKOVANJE
UPUTSTVO ZA RUKOVANJE
<ORIGINAL>
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
ΓΙΑ ΤΟΝ ΧΡΗΣΤΗ
PARA O UTILIZADOR
TIL BRUGER
FÖR ANVÄNDAREN
KULLANICI İÇİN
ЗА ПОТРЕБИТЕЛЯ
INFORMACJA DLA UŻYTKOWNIKA
FOR BRUKER
KÄYTTÄJÄLLE
ДЛЯ ПОЛЬЗОВАТЕЛЯ
ДЛЯ КОРИСТУВАЧА
PRO UŽIVATELE
PRE POUŽÍVATEĽA
A FELHASZNÁLÓNAK
ZA UPORABNIKA
PENTRU UTILIZATOR
KASUTAJALE
LIETOTĀJIEM
SKIRTA NAUDOTOJUI
ZA KORISNIKA
ZA KORISNIKA
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Dansk
Svenska
Türkçe
Български
Polski
Norsk
Suomi
Русский
Українська
Čeština
Slovenčina
Magyar
Slovenščina
Română
Eesti
Latviski
Lietuviškai
Hrvatski
Srpski

Advertisement

loading
Need help?

Need help?

Do you have a question about the Mr. SLIM SFZ-M50VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric Mr. SLIM SFZ-M50VA

  • Page 1 <ORIGINAL> Packaged Air-Conditioners INDOOR UNIT SFZ-M25, M35, M50, M60, M71VA OPERATION MANUAL FOR USER English BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch MANUEL D’UTILISATION POUR L’UTILISATEUR Français BEDIENINGSHANDLEIDING VOOR DE GEBRUIKER Nederlands MANUAL DE INSTRUCCIONES PARA EL USUARIO Español ISTRUZIONI DI FUNZIONAMENTO PER L’UTENTE Italiano ΕΓΧΕΙΡΙΔΙΟ...
  • Page 2: Table Of Contents

    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste.
  • Page 3 - It may also be in violation of applicable laws. - MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant.
  • Page 4: Parts Names

    2. Parts Names ■ Indoor Unit SFZ-M·VA Fan steps 3 steps Vane – Louver – Filter Normal Filter cleaning indication – ① Air inlet at the bottom ② Air inlet at the front Ⓐ Filter Air flow Ⓐ Ⓐ ① ②...
  • Page 5 2. Parts Names Display The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.) <Full mode>...
  • Page 6 2. Parts Names ■ Wireless Remote-Controller (option) SET TEMPERATURE button SET TEMPERATURE button ON/OFF button CHECK TEST RUN sets and any desired room MODEL SELECT Pushing button starts operation. temperature. Pushing again stops operation. NOT AVAILABLE AUTO STOP/AUTO START button FAN SPEED button TEMP ON/OFF This button is used to set fan...
  • Page 7: Operation

    3. Operation ■ About the operation method, refer to the operation manual that comes with each remote controller. 3.1. Turning ON/OFF 3.1.1. For wired remote controller [ON] [OFF] Press the [ON/OFF] button. Press the [ON/OFF] button again. The ON/OFF lamp will light up in The ON/OFF lamp will come off, and green, and the operation will start.
  • Page 8 3. Operation Information for multi system air conditioner (Outdoor 3.3.2. For wireless remote controller unit: MXZ series) ► To decrease the room temperature: button ③ to set the desired temperature. Press ► Multi system air conditioner (Outdoor unit: MXZ series) can The selected temperature is displayed 3.
  • Page 9 3. Operation 3.5. Ventilation (For wired remote controller) <Returning to the Operation menu> 3.5.1. Navigating through the Main menu Press the [RETURN] button to go back to the Operation menu. <Accessing the Main menu> Press the [MENU] button. The Main menu will appear. 3.6.
  • Page 10: Timer

    4. Timer ■ Timer functions are different by each remote controller. ■ For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller. 4.1. For wireless remote controller 1) Set the current time ①...
  • Page 11: Trouble Shooting

    7. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. ■ Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■ Make sure that there is plenty of space around the outdoor unit. Is the indoor unit air intake or outlet blocked? ■ Has a door or window been left open? When heating operation starts, warm air does not blow from the indoor ■...
  • Page 12: Specifications

    7. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. ■ The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room. Low sound- High sound- absorbing Normal rooms absorbing rooms rooms Broadcasting Reception Location Office, hotel studio, music room, hotel examples room room, etc.
  • Page 13 0.095 Note: Recycle Rating condition Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality Cooling - Indoor: 27ºC DB, 19ºC WB materials and components which can be recycled and reused. Electrical and electronic Outdoor: 35ºC DB, 24ºC WB equipment, at their end-of-life, should be disposed of separately from your household Heating - Indoor: 20ºC DB, 15ºC WB...
  • Page 14 Schallleistungspegel Ниво на звуковата мощност Müravõimsustase (ggf. je Geschwindigkeitseinstellung) (за отделните настройки на оборотите, ако е (kiiruse kohta, kui asjakohane) приложимо) Niveau de puissance acoustique Poziom mocy akustycznej Akustiskās jaudas līmenis (pour chaque réglage de la vitesse, si disponible) (w stosownych przypadkach w zależności od (attiecīgā...
  • Page 15 DICHIARAZIONE DI CONFORMITÀ CE PROHLÁŠENÍ O SHODĚ EU ЕС ДЕКЛАРАЦИЯ ЗА СЪОТВЕТСТВИЕ MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD. 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND MADE IN THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 16 UK DECLARATION OF CONFORMITY MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD. 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND MADE IN THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: MITSUBISHI ELECTRIC, SFZ-M25VA*, SFZ-M35VA*, SFZ-M50VA*, SFZ-M60VA*, SFZ-M71VA* * : , , 1, 2, 3, ·...
  • Page 17 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 18 <MAGYAR> Az eredeti szöveg angol nyelven íródott. A más nyelven írt változatok az eredeti szöveg fordításai. FIGYELMEZTETÉS • A hűtőközeg szivárgása fulladást okozhat. Gondoskodjon a szellőzésről az EN378-1 szerint. • Feltétlenül gondoskodjon a csövek szigeteléséről. A fedetlen csövek közvetlen megérintése égési vagy fagyási sérülést okozhat.
  • Page 20 This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN VG79D960H02_en...