  • Page 1 Installation manual R-TG 108p.3, R-TG 108n.3, R-TG 108h.3, R-BG 108h.3, R-BG 108n.3, C-TG 144p.2, R-BF 108p.3, R-BF 108n.3, R-BF 120p.2, R-WF 108p.3, R-WF 108n.3, R-WF 120p.2, R-WF 120p.2-CH, C-WF 144p.2, L-TG 120p.2, R-WF 48p, R-WF 60p...
  • Page 2: Table Of Contents

    4.3 Fastening with suitable laminate clamps 4.4 Clamping ranges and permissible load capacities 5. Electrical installation 5.1 Interconnection 5.2 Grounding 5.3 Check before commissioning 6. Maintenance and servicing 7. Malfunction and complaint 8. Disposal and recycling Superior Solar Solutions www.solyco.com...
  • Page 3: Introduction

    If used and treated properly, SOLYCO PV modules will work reliably for decades. As a result, SOLYCO PV modules generate a reliable yield. We wish you a bountiful harvest. As a result, SOLYCO PV modules generate a reliable yield. We wish you a good harvest.
  • Page 4: Closure Clause

    SOLYCO Solar AG accepts no responsibility or liability whatsoever for loss, damage or costs resulting from or in any way connected with faulty installation, improper operation and improper use or maintenance. The general terms and conditions of business and warranty of SOLYCO Solar AG apply. The warranty con- ditions can be found at www.solyco.com.
  • Page 5: General Safety Instructions

    The modules are approved for operating temperatures of -40°C to +85°C. ■ The maximum recommended installation height for SOLYCO PV modules is 2000m. ■ Due to salty sea air, the modules should be installed at least 3km from any body of salt water.
  • Page 6: Transportation

    You should immediately check the delivered goods and their packaging for transport damage. If you notice any damage, it is essential to note the damage on the delivery note. The damage should be described in detail per pallet and supported by photographic documentation. Have the forwarding agent countersign the notes. Superior Solar Solutions www.solyco.com...
  • Page 7: Mechanical Assembly

    The modules must be installed without voltage. The modules do not serve as a flexurally rigid connecting or fastening element. The SOLYCO PV modules are suitable for roof-mounted and ground-mounted systems. For mounting on roofs, use materials suitable for the application.
  • Page 8: Fastening With Suitable Laminate Clamps

    4.3 Fastening with suitable laminate clamps The frameless modules must not be mounted with any clamps. The laminate clamps should be approved by SOLYCO Solar AG prior to installation. The use of non-approved lami- nate clamps will void any product and performance warranty claims.
  • Page 9 The support rail runs parallel to the short sides. Module type Max. pressure Max. suction load Mounting posi- load tion Inner R-TG 108n.3 5400Pa 2400Pa mounting holes R-TG 108p.3 5400Pa 2400Pa „ R-TG 108h.3 5400Pa 2400Pa „ R-BG 108n.3 5400Pa 2400Pa „...
  • Page 10 Module type Max. pressure Max. suction load Mounting posi- load tion Outer R-TG 108n.3 2400Pa 2400Pa mounting holes R-TG 108h.3 2400Pa 2400Pa „ R-TG 108p.3 2400Pa 2400Pa „ R-BG 108h.3 2400Pa 2400Pa „ R-BG 108n.3 2400Pa 2400Pa „ R-WF 108n.3 2400Pa 2400Pa „...
  • Page 11 The support rail runs parallel to the short sides. Module type Max. pressure Max. suction load Mounting posi- load tion R-TG 108n.3 2400Pa 2400Pa D = ¼ L ±50mm R-TG 108p.3 2400Pa 2400Pa „ R-TG 108h.3 2400Pa 2400Pa „ R-BG 108n.3 2400Pa 2400Pa „...
  • Page 12 Module type Max. pressure Max. suction load Mounting posi- load tion R-TG 108n.3 2400Pa 2400Pa D = 1/5 W ±50mm R-TG 108p.3 2400Pa 2400Pa „ R-TG 108h.3 2400Pa 2400Pa „ R-BG 108n.3 2400Pa 2400Pa „...
  • Page 13 Module type Max. pressure Max. suction load Mounting posi- load tion R-TG 108n.3 2400Pa 2400Pa Corner points short side R-TG 108p.3 2400Pa 2400Pa „ R-TG 108h.3 2400Pa 2400Pa „ R-BG 108n.3 2400Pa 2400Pa „...
  • Page 14 Module type Max. pressure Max. suction load Mounting posi- load tion Insertion system R-TG 108n.3 5400Pa 2400Pa - long side R-TG 108p.3 5400Pa 2400Pa „ R-TG 108h.3 5400Pa 2400Pa „ R-BG 108n.3 5400Pa 2400Pa „...
  • Page 15 The support rail runs parallel under the short sides. Module type Max. pressure Max. suction load Mounting posi- load tion Insertion system R-TG 108n.3 2400Pa 2400Pa - short side R-TG 108p.3 2400Pa 2400Pa „ R-TG 108h.3 2400Pa 2400Pa „ R-BG 108n.3 2400Pa 2400Pa „...
  • Page 16 There are no module supports running under the modules or under the module frame. Module type Max. pressure Max. suction load Mounting posi- load tion L-TG 120p.2 1600Pa 1600Pa D = 300-400mm Superior Solar Solutions www.solyco.com...
  • Page 17: Electrical Installation

    Risk of death from electric shock and electric arc Consider locally applicable standards and regulations. SOLYCO PV modules are classified in application class A (certified according to IEC 61730) and comply with protection class II, provided that electrical installation has been carried out in accordance with regu- lations.
  • Page 18: Grounding

    Even if the modules are certified according to protection class II, the circumstances may require the ins- tallation of equipotential bonding. SOLYCO PV modules have 5.1mm (Ø) ground bores (6x) in all 4 poles and offer the option of installing equipotential bonding cables to ground the system.
  • Page 19: Maintenance And Servicing

    Defective or old solar modules must be disposed of properly and must not be disposed of along with household waste. We offer our customers the return of SOLYCO PV modules and their recycling. For more information, you can contact us by e-mail or telephone, or at The company SOLYCO SOLAR AG is registered as a manufacturer of the device type Large Photovoltaic Modules under the WEEE Reg.