Advertisement

user manual
D U S T E X T R A C T I O N S Y S T E M S
DM-120 B
DM-160 B
DM-200 B
Manufacturer: Riedex BV
Hoofdstraat 17
NL 8811 HD RIED
Tel. +31 (0)517 26 92 41
e-mail: info@riedex.nl
www.riedex.nl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM-200 B and is the answer not in the manual?

Questions and answers

Summary of Contents for Riedex DM-200 B

  • Page 1 D U S T E X T R A C T I O N S Y S T E M S DM-120 B DM-160 B DM-200 B Manufacturer: Riedex BV Hoofdstraat 17 NL 8811 HD RIED Tel. +31 (0)517 26 92 41 e-mail: info@riedex.nl...
  • Page 2 The manufacturer rejects all liability for damage re- sulting from the use of the extraction unit or the information given in this instruction manual. © 2020, Riedex BV, the Netherlands. No part of this publication may be copied or made public by print, photocopying, microfilm, electro- nic or in any other way without prior written per- mission to do so.
  • Page 3: Table Of Contents

    taBle of contents aBle of contents chapter page taBle of contents user Manual general safety regulations safety regulations for Maintenance repairs anD aDjustMents safe work MethoD Description of the Machine installation Maintenance Malfunctions recycling annexes dm-120B technichal drawing dm-120B spare parts dm-160B technichal drawing dm-160B...
  • Page 4: User Manual

    user manual user Manual WARNINGS AND SYMBOLS The following warnings and symbols are used in this manual: Gives suggestions and advice so The warnings contain important information. as to make certain tasks easier or Make sure everybody who uses the extraction more convenient.
  • Page 5 user manual USER MANUAL This instruction manual describes the installati- on, operation, use and maintenance of the ex- NOTE traction unit. In some instances, the diagrams and drawings that have been used may deviate from the actual situation. Read this instruction manual carefully! Follow the instructions before using the extraction unit.
  • Page 6 user manual USERS The term ‘user’ is defined as anyone who ope- rates, maintains, adjusts, cleans, repairs or per- forms any other work on or with the extraction unit. This user manual on the use of the extraction unit must be handed to the user, taking their level of education into consideration.
  • Page 7: General Safety Regulations

    safety general safety regulations The extraction unit meets all the relevant safe- ty regulations and has, therefore, been awarded WARNING the CE mark. Observe the general safety Various technical measures have been taken in regulations. accordance with the CE guidelines and harmoni- zed standards so that the extraction unit meets the safety requirements based on the current state of technology.
  • Page 8 safety GUARDS Before using the extraction unit, fit all the doors DANGER and hatches to the machine and secure them using the correct attachment aids. RISK OF FIRE AND EXPLOSION Avoid sparks or other possible sour- VISITORS AND CHILDREN ces of ignition at all times. Suction Keep visitors and, in particular, children, who are hoses must be electrically conduc- not aware of the dangers, away from the extrac-...
  • Page 9 safety WORK AREA Ensure the work area is safe when the extraction unit is in use. Keep a safe distance from the suc- WARNING tion openings. FIRE RISK! TOOLS Incorrect installation and opera- Always use the correct tools for the job at hand. tion can cause a fire.
  • Page 10 safety ORIGINAL ACCESSORIES Replacement parts and accessories must meet NOTE the requirements specified by the manufacturer. Therefore, only use original replacement parts and original accessories or the replacement parts Any use of the machine outside of its and accessories approved by the manufacturer. intended use is prohibited and is con- sidered improper.
  • Page 11: Safety Regulations For Maintenance , Repairs And Adjustments

    safety safety regulations for Maintenance repairs anD aDjustMents HOISTING Always take the weight of components into con- WARNING sideration whenever they are hoisted. Use the correct tools and employ a safe hoisting method. Never stand or walk under hoisted components. Always observe the safety regulations Falling objects may cause serious injury.
  • Page 12: Safe Work Method

    safety safe work MethoD OPERATORS The machine operators must read this instruc- tion manual so that they can use the extraction WARNING unit safely and correctly. Observe the following safety regulati- GENERAL INFORMATION ons to ensure the work is carried out Always start the extraction unit first before using safely.
  • Page 13 safety SOUND PRESSURE LEVEL The sound pressure level of the machine is less than 65 dB (A)*. Hearing protection is recom- mended or prescribed in conjunction with other machines installed on the shop floor. We refer to the local legislation of the user's country. The specified sound pressure level values are emissi- on values of the extraction unit and therefore not safe workplace values.
  • Page 14: Description Of The Machine

    A CE-marked type plate with the data as shown than described in this manual is not in the adjacent figure is attached to the extractor permitted! unit. TECHNICAL DATA DM-120 B DM-120 HD DM-160 B DM-200 B Motor 2,2 kW 3 kW...
  • Page 15: Installation

    installation installation TRANSPORT The extraction unit is supplied completely assem- bled. The shipment is on a pallet and the machi- ne can be unloaded with a forklift. The device can be removed from the pallet by means of the lif- ting eyes (with forklift truck or crane).
  • Page 16 installation ELECTRICAL CONNECTION The extraction unit requires a 400 V, 50 Hz three-phase power supply with zero and ground WARNING to function. A fuse with class K16A must be used. Danger of electric current! • Write down the connection values on the Work on electrical equipment may type plate and check whether your mains only be carried out by qualified per-...
  • Page 17 CONTROL BOX HAUPTSCHALTER INTERIOR transformator DM-120M fuses main switch/Emergency-off = switch off power duration reset fan BEDEUTUNG LAYOUT ZEICHNUNG - SCHRANK A Riedex B.V. Funktion Hoofdstraat 17 8811 HD Ried reset cleaning The Netherlands info@riedex.nl BEDEUTUNG LAYOUT ZEICHNUNG - MONTAGEPLATTE ANZICHT...
  • Page 18 installation CONNECTING HOSE AND/OR PIPING When connecting a hose, only conductive and flame-retardant hoses may be used. It is impor- tant that the electrical connection between the For the operation of the filter cle- hose and the inlet of the extraction unit is pro- aning it is necessary to connect the per.
  • Page 19: Use

    FIRST COMMISSIONING The following steps must be carried out during NOTE the initial commissioning of the extraction unit: DIRECTION OF ROTATION • Check the direction of rotation of the fan. This Stop the machine immediately if a must match the arrow stickers. A wrong direc- wrong direction of rotation is detec- tion of rotation can be recognized by a very ted, to prevent excessive heating.
  • Page 20 WASTE DISPOSAL Dust and chips are collected in the waste con- tainers during operation. The level can be che- cked through the viewing window. Dust may Mechanical filter cleaning only be stored temporarily up to a total volu- Every time the extraction unit is swit- me of 500 liters.
  • Page 21 CONNECTING MULTIPLE MACHINES If more than one machine is connected to the ex- traction unit, each machine must be shut off with a slider from the extraction unit. Make sure that the sliders on the machines that are not being If the yellow 'pressure difference used are closed.
  • Page 22: Maintenance

    maintenance Maintenance PERIODIC MAINTENANCE The extraction unit is low in maintenance. The bearings of all applied motors are lubricated for WARNING life. Repairing the extraction unit is only Continuous work: permitted by authorized and quali- DAILY: fied personnel, with sufficient trai- •...
  • Page 23: Malfunctions

    malfunctions Malfunctions THE EXTRACTION UNIT WON'T START • No main voltage, check the fuses. WARNING • Main switch is set to 0/Off. • Error in the slider control (if used). See the cor- responding user manual. Do not work on the electrical com- ponents.
  • Page 24 malfunctions DE PLASTIC WASTE BAG IS PULLED INTO THE EXTRACTION UNIT • The waste bag is torn. • The waste container has not been slid far en- ough under the extraction unit. • The rubber seal on the bottom of the extrac- tion unit is damaged.
  • Page 25: Recycling

    disposal Disposal If, after many years of use, the extraction unit re- aches the end of its lifecycle, then remove it and dispose of it appropriately. Disconnect the ex- WARNING traction unit from the power supply by discon- necting the power from the machinery. Remove Be aware of possible risk of being cut the fuses from the machinery.
  • Page 26: Annexes

    -120B technical drawing dm annexes...
  • Page 27: Spare Parts Dm-120B

    -120B spare parts dm 16 17 18 Pos Item no. Pce. Description F 162.100 Differential pressure switch Pos Item no. Pce. Description 2-pin three-phase motor F 160.370 F 169.500 Vibration motor 2,2 kW B5/1/2 M F 160.252 Ø 80 fixed wheel F 161.380 RRD-120 fan F 161.325...
  • Page 28: Technichal Drawing Dm-160B

    -160B technical drawing dm...
  • Page 29: Spare Parts Dm-160B

    -160B spare parts dm 16 17 18 Pos Item no. Pce. Description F 162.100 Differential pressure switch Pos Item no. Pce. Description 2-pin three-phase motor 3 F 160.370 F 169.500 Vibration motor kW B5/1/2 M F 160.252 Ø 80 fixed wheel F 161.380 RRD-160 fan F 161.325...
  • Page 30: Technichal Drawing Dm-200B

    -200B technichal drawing dm...
  • Page 31: Spare Parts Dm-200B

    -200B spare parts dm 16 17 18 Pos Item no. Pce. Description F 162.100 Differential pressure switch Pos Item no. Pce. Description 2-pin three-phase motor 4 F 160.370 F 169.500 Vibration motor kW B5/1/2 M F 160.252 Ø 80 fixed wheel F 161.380 RRD-200 fan F 161.325...
  • Page 32: Pneumatic Schedule For Compressed Air Cleaning

    annex pneumatic schedule for compressed air cleaning Compressed air tank DM-120 t/m DM-250 DM-300 DM-350 DM-200 Content (liter) 15,1 18,6 22,9 Max. limit pressure Operating pressure Number of valves Pos. Item no. Description F200.001 Compressed air tank F200.002 Solenoid valve C25DD 1" 224 VD F200.003 Filter pressure regulator NL G½...
  • Page 33: Eg-Declaration Of Conformity

    CE mark. Any change to the machine that has not been agreed with us will result in the immediate loss of the declaration of validity. Ing. R. Faber, director Riedex BV The undersigned of this declaration is the authorized representative for com-...
  • Page 34: Eg - Declaration Of Conformity For Control Box

    The undersigned of this declaration is the authorized representative for compiling the technical documenta- tion. Ried, The Netherlands, 17.8.2020 Ing. R. Faber, director Riedex BV...
  • Page 35: Gs - Certificate

    certificate...
  • Page 36: Notes Repair History

    notes repair history...

Table of Contents