SAFETY
INFORMATION
Continued
16. Do not operate heater if any log is bro-
ken. Do not operate heater if a log is
chipped (dime-sized or larger).
17. To prevent performance problems, do
not use propane/LP fuel tank of less
than 100 lbs. capacity.
18. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Screen
Logs
Heater Controls
(Inside Door)
Figure 1 - Vent-Free Propane/LP Gas Stove
107435

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
This heater is designed for vent-free opera-
tion. State and local codes in some areas
prohibit the use of vent-free heaters.
3
OWNER'S MANUAL
UNPACKING
1.
Remove top inner pack.
2.
Tilt carton so that stove is upright.
3.
Remove protective side packaging.
4.
Slide stove out of carton.
5.
Remove protective plastic wrap.
6.
Remove screen by lifting and then pull-
ing forward.
7.
Remove log set by cutting plastic ties.
8.
Carefully unwrap log.
9.
Check for any shipping damage. If
stove or log is damaged, promptly in-
form dealer where you bought stove.
PRODUCT
FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system.
The ODS is a required feature for vent-free
room heaters. The ODS shuts off the heater if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
Stove
Cabinet
For more information, visit www.desatech.com