Summarization of Contents

The Refrigerant
Safety Warning for Refrigerant
Important warnings regarding the safe handling and operation with R32 refrigerant.
Notices for Usage
Operating Range
Specifies the valid outdoor and indoor temperature ranges for cooling and heating modes.
Emergency Operation
Airflow Direction Adjustment
Instructions on how to adjust the vertical and horizontal airflow direction of the unit.
Description of Parts
Indoor Unit
Diagram and labels identifying the components of the indoor air conditioning unit.
Outdoor Unit
Diagram and labels identifying the components of the outdoor air conditioning unit.
Remote Control User Guide
General Warnings
Important safety instructions and precautions for using the remote control effectively and safely.
Buttons Description
ON/OFF Button
Function of the power button to turn the unit on/off and reset timer/SLEEP.
°C/°F Button
How to select temperature units between Celsius and Fahrenheit for display.
SPEED Button
Controls fan speed settings: Low, Mid, High, and Auto.
Buttons Description
iFEEL Button
Activates the iFeel function to sense and display room temperature.
TIMER Button
Allows setting of operational timers for the air conditioner.
HEALTH/ICLEAN Button
Provides functions for health maintenance and self-cleaning of the evaporator.
TURBO Button
Activates TURBO mode for maximum fan speed in COOL or HEAT mode.
Buttons Description
MODE Button
Selects operating modes: AUTO, COOL, DRY, HEAT, and FAN.
SLEEP Button
Activates Sleep mode for gradual temperature adjustment during cooling or heating.
Anti-F Button
Activates drying and anti-mold function to prevent odor and mold formation.
Buttons Description
ELE.H/ECO Button
Activates ECO mode for low electricity consumption; ELE.H function is not available.
User Guide
Automatic Mode (AUTO)
Step-by-step guide for operating the air conditioner in Automatic mode.
Cooling/Heating Mode
Step-by-step guide for operating the air conditioner in Cooling or Heating modes.
Dry Mode
Step-by-step guide for operating the air conditioner in Dry mode.
Wi-Fi Guide (Optional)
Introduction
Overview of Wi-Fi module for remote control via mobile terminals.
Download and Install Control Software
Instructions for downloading and installing the 'AC Freedom' control software.
Wi-Fi Guide (Optional)
Smartphone, Pad or Other Mobile Terminals Connect to Wi-Fi or Hotspot
Guidance on connecting mobile devices to Wi-Fi or hotspot for remote control.
Configuration of Devices
Steps to configure AC devices after downloading and installing the control software.
Wi-Fi Guide (Optional)
Modify and Lock the Devices
Instructions for renaming, changing icons, and locking AC devices within the app.
Wi-Fi Guide (Optional)
Delete an AC under Control
How to remove an air conditioner from the control app.
Remote Control with Wireless Router
Enabling remote control via wireless router and GPRS.
Clean and Care
Clean the Panel
Instructions for cleaning the front panel of the indoor unit with a cloth and lukewarm water.
Clean the Air Filter
Steps to remove and clean the air filter using a vacuum cleaner or water.
Troubleshooting
The Air Conditioner Does Not Work
Troubleshooting steps for when the air conditioner fails to start or operate.
The Air Conditioner Can't Run After Immediate Start-up
Explanation for delays in operation after immediate start-up due to protective functions.
The Air Conditioner Stops Running After a While
Reasons for the unit stopping after a period, including temperature limits and defrosting.
Poor Cooling/Heating Effect
Causes for poor cooling/heating effect, such as dust, blockages, and incorrect settings.
The Indoor Unit Makes Abnormal Sound
Potential causes for abnormal sounds, like dust, high fan speed, or refrigerant flow.
Notices for Installation
Safety Operation of Flammable Refrigerant
Requirements for qualified personnel and manufacturer's methods for refrigerant system repair.
Installation Notes
Key considerations for installing the air conditioner, avoiding heat sources and ensuring proper setup.
Notices for Installation
Welding
Procedures and safety steps for welding refrigerant system pipes during maintenance.
Electrical Connection Requirements
Requirements for Operations at Height
Safety measures including wearing safety belts when installing at heights above 2m.
Others
Installation for Indoor Unit
Guidelines and dimensions for the physical installation of the indoor unit.
Dimension Drawing of Indoor Unit Installation
Detailed dimensions and clearances required for indoor unit installation.
Mounting Plate
Instructions for installing the mounting plate securely for the indoor unit.
Wall-Through Hole
Procedure for creating the wall hole for piping, including angle and size recommendations.
Route of Pipeline
Drain Pipe Connection
Steps for connecting the drain pipe to the indoor unit and ensuring proper drainage.
Wrap the Piping
Instructions for insulating and securing the piping and cables for protection and condensate prevention.
Interconnection Cord Installation
Connect Interconnection Cord of Indoor Unit
Detailed steps for connecting the interconnection cord to the indoor unit's wiring terminals.
Installation for Outdoor Unit
Dimension Drawing of Outdoor Unit Installation
Diagram showing dimensions and bolt hole locations for outdoor unit installation.
Refrigerant Connections
Specifications for refrigerant piping length, additional charge, and height differences.
Install the Connection Pipe
Wiring Connection
Detailed steps for making the electrical wiring connections to the outdoor unit.
Check After Installation
Post-Installation Checks
Comprehensive checks covering electrical safety, installation integrity, and refrigerant leak detection.
Test Operation Preparation and Method
Steps for preparing and performing operational tests of the air conditioner.
Appendices
Piping Configuration
Details on connecting pipe diameters for liquid and gas lines and additional refrigerant requirements.
Procedure for Extending the Piping
Step-by-step guide for cutting, deburring, and expanding pipes for extending refrigerant lines.
Appendices
Secure an Insulating Tube
Instructions for securing an insulating tube onto the pipe for protection.
Install a Union Nut
Procedure for removing the union nut and installing it onto the pipe.