Keypad LEDs
W
ARMED LED DEFINITION
Armed
Instant Mode
Zone in Alarm
READY LED DEFINITION
X
Ready to be Armed
Zone faulted
HSYSTEM LED DEFINITION
AC Failure
System Trouble(s)
FIRE LED DEFINITION
Fire Alarm
Fire Memory/*Fire Trbl
*See Note 1
AC LED DEFINITION
AC Present
AC Failure
ZONE LED DEFINITION
Faulted Zone
Bypassed Zone
Zone in Alarm
N
:
OTE
* If Fire Trouble on Fire LED [96-4] has been enabled, a steady
Fire LED will indicate Fire Trouble.
8

Panel Operation

Arming (System ON)
ON
Before arming the system close all protected
Rapid Flash
zones (unless programmed as Auto-Bypass
Flashing
Reentry Zones).
code, the keypad will provide a feedback beep
for each key pressed.
code is entered, the keypad will beep 3 times. If
ON
an incorrect Arm/Disarm code is entered, the
OFF
keypad will sound a 1-second tone indicating an
incorrect entry.
Flashing
Arming without Entry Delay (Instant
ON
Mode)
Enter the
The
W
ARMED LED will flash rapidly to indicate
Flashing
the panel is in Instant Mode. If an Exit/Entry
ON
Zone is tripped while the panel is in Instant
Mode the panel will go into alarm immediately.
Arming/Disarming with a Keyfob
ON
The system can be armed by pressing the
OFF
key, and disarmed by pressing the
the Keyfob. Zones programmed as Exit/Entry
Follower Zones can be bypassed when the
ON
or
N
Slow Flash
programmed for Interior
Flashing
programmed as Home/Away with Delay Zones
can be armed regardless of the state of the Exit/
Entry Zones when the
Keyfob have been programmed for Full Set [81-
Enter a 4-digit Arm/Disarm
If a valid Arm/Disarm
to eliminate the entry delay.
A 1
L
keys on the Keyfob have been
[81-84].
or
keys on the
M
N
84]. To arm the system with all zones protected,
press the
key. Press and hold the
K
key for 1.5s to fully set the system (the LED
N
on the Keyfob indicates the Keyfob has
transmitted the signal).
Keyswitch Chirp [23-4] for an audible indication
of system arming and disarming.
Arming/Disarming with a Keyswitch
The system can be armed/disarmed by using a
momentary
Keyswitch
Program Keyfob/Keyswitch Chirp [23-4] for an
audible
indication
disarming.
N
:
OTE
Faulted Keyswitch or silent 24 hour zone normally do not
display at the keypad. If a silent 24 hour zone or Keyswitch
is faulted at the time of arming the faulted zone will display
only while the priority sound is ON.
Arming Instant with a Keyfob
The panel can be ARMED INSTANT when the
K
or
keys on the Keyfob have been
M
N
key on
programmed for Instant [81-84]. To arm the
system with Instant protection press the
M
key, then press and hold the
1.5s to arm the panel with INSTANT protection.
Zones
Disarming (System OFF)
After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry
or
M
Program Keyfob/
wired
to
Zone
6.
of
system
arming
and
K
or
key for
M
N

Hide quick links: