5. CCTV: Any camera represented on the map will be able to be viewed by simply
right clicking the mouse and choosing view camera.
II. NAPCO Burglar Alarm Integration:
1. The NAPCO panels that will be supported are the GEM P3200, P9600 and X255.
The integration will support receiving event information from the NAPCO panels,
as well as arming and disarming of NAPCO panels from the CardAccess 3000
system. Arming and disarming of NAPCO panels may be by means of reader(s)
in the CardAccess 3000 system, as well as manually through an interface similar
to the current manual control interfaces in the CardAccess 3000 GUI. It allows
unlimited number of cardholders to be programmed for arming and disarming.
2. General Description: The integration will include CardAccess 3000 GUI
(Display Screen) to display NAPCO alert types. All events generated will have to
be configured to display pending status, priority and/or response required. All
these changes must be made through the CardAccess 3000 configuration
screens and stored in the same database as the CardAccess 3000 system.
3. Hardware and Communications
a. There must be one physical serial port for each NAPCO panel to be
connected via serial communications or, the NAPCO panel must be
capable of interfacing over an existing network via a Napco Netlink
TCP/IP interface module. All network communication will be encrypted.
b. All settings changes will be logged in the current ACS Audit Trail table.
New audit trail types will denote changes in the NAPCO integration.
These changes will be available in the audit trail display as well as in
reports. This includes arming and disarming of NAPCO panels, and
configuration changes.
d. Visual indication of the alarm area armed/disarmed status will be
available at the ACS reader.
4. Communication Software Module
a. Will receive events from the NAPCO panels.
b. Will perform arming and disarming functions on the NAPCO panels.
c. The system shall handle permissions on the NAPCO panels.
d. Will have the ability to select any Napco event to trigger a CardAccess
3000 event and/or activate DVR recording through CA3000.
e. Will have the ability for the user to partition Napco panels by privilege
level.
5. Configuration Screens:
a. The configuration screen will allow the user to set up the link between
the NAPCO panels and the CardAccess 3000 system. The
configuration screens will be available through the CardAccess 3000
GUI in a manner similar to the existing configuration screens in the
CardAccess 3000 GUI.
ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2.7