Instructions for Assembly, Testing, Operation, Servicing, and Storage
Bleach Pump with Motor Shield: For use with bleach**
READ and UNDERSTAND the Owner's Manual completely before using this pump.
Assemble, test, and use only in accordance with the Owner's Manual instructions.
EXERCISE CAUTION when mixing chemicals, as incorrect ratios or mixtures could
release harmful gases.
READ and FOLLOW chemical safety instructions.
KNOW emergency procedures BEFORE handling chemicals. Pump leaks, bodily chemical
contact, poisoning, and spills require immediate response.
AVOID inhaling, ingesting, or coming into contact with any chemicals.
WEAR personal protective gear when operating, cleaning, and servicing the pump.
KEEP pump and spray materials away from children and pets. Some chemicals are
especially toxic to them.
DO NOT TURN ON POWER to pump until ready to spray in order to avoid unintentional
spray release.
SOAK vegetation well in the area surrounding the work zone prior to and after spraying
bleach. Bleach can kill vegetation if not soaked thoroughly.
ALWAYS keep a fire extinguisher rated "ABC" nearby.
Improper use of the pump or handling of chemicals could result in serious injury, illness
to the operator or nearby persons/animals, or could cause damage to the environment.
**This pump is recommended for use in spraying bleach. The pump will be damaged, and warranty
voided if used to apply any petroleum-based product (gasoline, diesel, kerosene, or oil). The pump
should not be used to transfer any product intended for human consumption. WE RECOMMEND
THAT THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS BEEN USED FOR
SPRAYING BLEACH. Any chemical will leave some residual in the pump components, even after
the pump has been properly cleaned. These residual chemicals can have unexpected effects on future
uses. This pump should not be used by people with reduced physical, sensory, or mental capabilities
or by those who lack experience or knowledge of product use.
Any Questions, Comments, Problems, or Parts Orders
Call Everflo Product Support at 1-800-864-1649
Owner's Manual
WARNING
EFSW-MANUAL
ITEM NUMBER: EFSW2200,
EFSW4000,EFSW5500
SERIAL NUMBER: __________
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EFSW5500 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Summary of Important Information
General Chemical Safety
General Chemical Safety guidelines and precautions for handling chemicals.
Installation
Step One: Mounting
Instructions for mounting the pump in a suitable location.
Step Two: Plumbing
Guidance on connecting hoses and fittings to the pump.
Step Three: Connect pump to battery or 12V DC supply
Detailed steps for connecting the pump to a 12V DC power source.
Step Four: Check and test completed assembly
Procedures for verifying the pump assembly and testing for leaks.
Features
Motor Shield System
System that shuts off pump in case of leaks to prevent motor damage.
ON/OFF Switch
Control for turning the pump operation on and off.
LED Indicator
Indicates a fluid leak inside the pump cartridge.
Pressure Switch
Reacts to pressure, interrupting power at shut-off pressure.
Quick Connect Ports
Allows for quick and easy fitting removal.
Pump Cartridge
The component that moves fluid, easily replaceable when worn.
Operation – Important Safety Information
General Chemical Safety
General Chemical Safety guidelines and precautions for handling chemicals.
Chemical Application Safety
Safety measures for applying chemicals during operation.
Chemical Accident Procedures
Procedures for responding to chemical spills, leaks, and personal exposure.
Operation – Preparing the Pump for Each Use
Ensure Clean System
Ensuring the pump system is clean before subsequent use.
Inspect and Repair
Instructions for inspecting and repairing the pump system.
Operation – Using the Pump
Assess Wind and Clear Area
Checking wind conditions and clearing the work area before spraying.
Operate the Pump
Steps for safely turning on and operating the pump.
Pressure Switch Operation
Explanation of how the pressure switch controls pump operation.
Mixing Soft Wash Mix
Instructions for mixing bleach and surfactant for cleaning solutions.
Before Spraying
Final checks and preparations before commencing spraying.
Spraying Roofs with Soft Wash Mix
Procedure for spraying roofs using the soft wash mix.
Spraying Siding with Soft Wash Mix
Procedure for spraying siding using the soft wash mix.
Spraying Fences and Decking
Procedure for spraying fences and decking with soft wash mix.
Rinsing
Instructions for rinsing surfaces and vegetation after spraying.
Leaving Unattended
Procedures for safely leaving the pump unattended.
Discontinuing Use
When to stop using the pump due to clogging or malfunction.
Clean Pump and Decontaminate
Steps for cleaning the pump and personal decontamination after use.
Storage
Preparing for Storage
Instructions for preparing the pump for long-term or winter storage.
Removing from Storage
Steps to take when taking the pump out of storage.
Troubleshooting
Before Attempting Service
Safety precautions and preparatory steps before troubleshooting.
Problem/Cause/Solution Guide
Guide to common problems, their causes, and solutions.
Maintenance
Pump Cartridge Replacement
Detailed instructions for replacing the pump cartridge.
Specifications
Model Specifications
Technical details including flow, pressure, dimensions, and weight.
Accessories
Available Accessories
Lists available accessories and their compatibility with pump models.
Limited Warranty
Warranty Terms and Exclusions
Details the terms, duration, and exclusions of the product warranty.