TROUBLESHOOTING
28
TROUBLESHOOTING
Continued
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
• Immediately call your gas supplier from a neighbor's phone. Follow the
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
Fireplace produces unwanted odors
Fireplace shuts off in use
Gas odor even when control knob is in OFF
position
Gas odor during combustion
Dark residue on logs or inside of fireplace
For more information, visit www.desatech.com
For more information, visit www.desatech.com
WARNING: If you smell gas
building.
gas supplier's instructions.
POSSIBLE CAUSE
1. Gas leak. See Warning statement
above
1. High or gusting winds
2. Low line pressure
3. Pilot is partially clogged
4. Inner vent pipe leaking exhaust gasses
into system
5. Horizontal vent improperly pitched
6. Glass too loose and air tight gasket leaks
in corners after usage
7. Bad thermopile or thermocouple
8. Improper vent cap installation
1. Gas leak. See Warning statement
above
2. Control valve defective
1. Gas leak. See Warning statement
above
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
REMEDY
1. Locate and correct all leaks
1. Fireplace has been tested for up to
40mph winds. However, extreme con-
ditions may occur
2. Contact local propane/LP or natural gas
company
3. Clean pilot
4. Locate and correct all leaks
5. Horizontal vent termination should slope
down only enough to prevent any water
from entering the unit. The maximum
downward slope of the vent termination
is 1/4" for any horizontal run
6. Tighten glass
7. Replace faulty component
8. Check for proper installation and free-
dom from debris or blockage
1. Locate and correct all leaks
2. Replace control valve
1. Locate and correct all leaks
1. Properly locate logs
2. Clean out air holes at burner inlets. Pe-
riodically repeat as needed
3. Remove blockage
105706-01B