Desa VDCFTNB Owner's Operation And Installation Manual page 11

Desa owner's operation and installation manual unvented (vent-free) gas compact classic hearth dual burner fireplace vdcftnb, vdcftpb, vdcfrpb,vdcfrnb
Table of Contents

Advertisement

INSTALLATION
Continued
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with wall.
An optional trim kit accessory is available (see
Accessories, page 40). Trim will extend past sides
of fireplace approximately 1/2 inch. This will cover
the rough edges of the wall opening. If installing
a built-in mantel above the fireplace, you must
follow the clearances shown in Figure 10, page
12. Follow the instructions below to install the
fireplace in this manner.
Height
Front Width
Depth
1. Frame in rough opening. Use dimensions shown
in Figure 7 for the rough opening. If installing in
a corner, use dimensions shown in Figure 8 for
the rough opening. The height is 26
is the same as the wall opening above.
2. If installing GA3450TA blower accessory, do
so at this time. Follow instructions included
with blower accessory.
Note: If not installing blower accessory, you
may wish to run electrical wiring to your
fireplace for future blower installation (see
Accessories, page 40). Use only approved
three-wire electrical wiring.
26
7
/
Figure 7 - Rough Opening for Installing
43
"
5
/
16
Figure 8 - Rough Opening for Installing
in Corner
116526-01A
Actual
Framing
26"
26
26
/
"
26
3
4
14
/
"
15
1
4
/
7
15
"
1
/
4
"
8
26
"
7
/
8
in Wall
30
26
7
"
/
8
61
"
1
/
4
www.desatech.com
WARNING: If pre-wiring, do
not connect wiring to any electri-
cal source at this time.
Install fireplace electrical outlet
and connect wiring to outlet
before connecting to electrical
source. The fireplace electri-
cal outlet is included with the
GA3450TA blower accessory.
Only use the fireplace electri-
cal outlet supplied with the
GA3450TA blower accessory.
Note: A qualified installer should make all electri-
cal connections.
/
"
7
8
3. Install gas piping to fireplace location. This
/
"
7
8
installation includes an approved flexible gas
/
"
1
4
line (if allowed by local codes) after the equip-
ment shutoff valve. The flexible gas line must
be the last item installed on the gas piping.
4. If you have not installed hood, follow instruc-
" which
tions on page 6.
8
5. Carefully set fireplace in front of rough opening
with back of fireplace inside wall opening.
6. Attach flexible gas line to fireplace gas regula-
tor. See Connecting Equipment Shutoff Valve
to Heater Control, page 17.
7. Bend four nailing flanges on outer casing with
pliers (see Figure 9).
8. Attach fireplace to wall studs using nails or
wood screws through holes in nailing flange.
9. Check all gas connections for leaks. See Check-
ing Gas Connections, page 17.
3/4" Off
The Floo r
Nails or
Minimum
Wood
Screws
5
"
/
8
Figure 9 - Attaching Fireplace to Wall
Wall Studs
Nailing
Flanges
Studs
11