INSPECTING BURNERS
Continued
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flames should
go up through the middle of logset. Flames should not "spill" to the
edges of the pan or sides of the logset.
Figure 37 shows a typical flame pattern. If burner flame pattern differs
from that described:
• turn appliance off (see To Turn Off Gas to Appliance, page 16)
• see Troubleshooting, pages 19 and 20
P324E and VP324E Models
P325E(B) and VP325E(B) Models
Figure 37 - Typical Flame Pattern
108794-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSPECTING BURNERS

CLEANING AND MAINTENANCE

CLEANING AND
MAINTENANCE
WARNING: Installation and repair should be done
by a qualified service person. The appliance should be
inspected before each use and at least annually by a
qualified service person. More frequent cleaning may
be required due to excessive lint from carpeting, bed-
ding material, pet hair, etc. It is imperative that the
control compartments, burners, and circulating air sys-
tem be kept clean.
WARNING: The logs can be hot. Handle only
when cool.
WARNING: Turn off gas and electrical power
before servicing appliance.
WARNING: Failure to keep the primary air
opening(s) of the burner(s) clean may result in soot-
ing and property damage.
PILOT AND BURNER
• Remove logs and ember material before cleaning burner and
replace when cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove
excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to log placement informa-
tion on pages 12 and 13 to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See Replacement Parts, page 18.
• Replace ember material periodically as needed. See Replace-
ment Parts, page 18.