Desa CDCFPR Owner's Operation And Installation Manual page 23

Unvented (vent-free) gas compact classic hearth dual burner fireplace
Table of Contents

Advertisement

OPERATING FIREPLACE
Continued
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 30. Also, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety inter-
lock system. Wait one (1) minute for system
to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burner should
light. Set control knob to any heat level
between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor
Thermocouple
Electrode
Figure 43 -Propane/LP Gas Pilot
111244-01F
Pilot Burner
www.desatech.com