Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Trerice Manuals
Controller
91600
Operation installation maintenance manual
Trerice 91600 Operation Installation Maintenance Manual
Self-operating temperature regulators indicating and non-indicating
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
page
of
24
Go
/
24
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Principles of Operation of the Regulator
Identifying Your Unit
Pressure and Temperature Limits
REGULATOR Installation
Sensing Bulb - Location & Installation
Placing Regulator into Operation & Setting Control Point
Routine Service
Stem Seal Packing
Checking the Regulator for Proper Action
Valve Body Assembly
Reversing the Valve Action
3-Way Regulator - Installation & Maintenance
Model 91600 - "Safety-Type" Installation & Maintenance
Typical Applications
Typical Heat Exchanger Application Using a Self-Op 2-Way Valve
Typical Heat Exchanger Application Using a Self-Op 3-Way Diverting Valve
Typical Plumbing for a Self-Op 3-Way Mixing Valve
Trouble-Shooting
Advertisement
Quick Links
1
Principles of Operation of the Regulator
Download this manual
Operation, Installation & Maintenance Manual
Series 91000
Self-Operating Temperature Regulators
Model 91400 Shown
Indicating and Non-indicating
Instruction Manual
IH-2
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the 91600 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Trerice 91600
Controller Trerice 91000 Series Operation Installation Maintenance Manual
Self-operating temperature regulators indicating and non-indicating (24 pages)
Controller Trerice 91400 Operation Installation Maintenance Manual
Self-operating temperature regulators indicating and non-indicating (24 pages)
Controller Trerice TR8938A90 Series Quick Start Instructions
1/4 din-96x96mm, universal ac power, universal temperature inputs, 4-20ma control output (2 pages)
Summarization of Contents
Principles of Operation
Identifying Your Unit 91000 & 91400 Actuators
Guide to identifying specific regulator models and their specifications.
Pressure and Temperature Limits
Installation
Location Selection for the Regulator
Factors to consider when selecting a suitable installation site for the regulator.
Regulator Installation Procedure
Steps and considerations for installing the regulator in the piping system.
Sensing Bulb
Sensing Bulb Location
Guidelines for optimal placement of the sensing bulb for accurate temperature readings.
Sensing Bulb Installation
Procedures for correctly installing the sensing bulb and its associated components.
Operation and Control Point Setting
Placing the Regulator into Operation
Steps to bring the regulator online and achieve initial operational status.
Routine Service and Maintenance
Stem Seal Packing
Replacing Valve Stem Packing
Detailed instructions for removing and installing new stem seal packing.
Checking for Proper Action
Inspecting the Actuator
Procedures to verify the functionality and responsiveness of the actuator.
Inspecting Valve Body Assembly
Steps to check the valve body for proper movement and potential blockages.
Valve Body Assembly
Removing Valve Body Assembly
Step-by-step guide to detach the valve body from the actuator.
Replacing Valve Body Assembly
Instructions for reattaching or installing a new valve body assembly.
Reversing Valve Action
Procedure for Reversing Valve Action
Detailed steps to alter the valve's operating direction (heating/cooling).
3-Way Regulators Installation & Maintenance
Model 91600 Safety-Type Installation & Maintenance
91600 Special Instructions
Specific guidance for installing and maintaining the Model 91600 safety-type regulator.
Typical Applications
Heat Exchanger Application (2-Way)
Illustrates heat exchanger setup using a self-operating 2-way valve.
Heat Exchanger Application (3-Way Diverting)
Shows heat exchanger setup with a 3-way diverting valve.
3-Way Mixing Valve Plumbing
Diagram for plumbing a 3-way mixing valve application.
Heating Application
Example of a typical heating system setup using the regulator.
Plating or Pickling Application
Illustrates regulator use in plating or pickling baths.
Trouble Shooting Guide
Erratic Control Issues
Identifies common causes and corrections for erratic temperature control.
Temperature Exceeds Control Point
Addresses issues where the controlled temperature is too high.
Temperature Below Control Point
Addresses issues where the controlled temperature is too low.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 91600 and is the answer not in the manual?
Questions and answers