Temperature
The factory settings should be sufficiently
accurate for normal usage. To calibrate the
temperature readout, first measure the water
temperature with a thermometer known to
be accurate.
Use the cursor keys to display the temperature
readout box, then increase or decrease the
value to match the measured temperature. The
temperature can be set from 32° to 99.9°F (0° to
37.7°C) with a resolution of 0.1° unit.
To change the units between °F (Fahrenheit) or °C
(Celsius), see section 3-6 Setup > Units.
Temp filter
Increase this setting to stabilise an erratic
temperature reading. Decrease to improve
reading responsiveness. The temperature filter
can be set from 0 to 30 seconds.
Fuel
WARNING
!
Extreme precautions must be observed
when carrying out this procedure.
Failure to do so could create hazardous
conditions that can cause serious personal
or property damage.
Calibrating the fuel usage can improve the
accuracy of fuel measurements.
Twin engine installations require each fuel
transducer to be calibrated. This can be done
at the same time with two portable tanks or at
different times using one portable tank.
Calibrating the fuel transducer(s) requires
accurate measurement of the fuel consumption.
This is best done using a small portable tank. At
least 4 gallons (15 litres) of fuel should be used to
ensure an accurate calibration.
It is often very difficult to fill underfloor tanks to
the same level twice due to air pockets, so the
more fuel used, the more accurate the calibration.
To calibrate the fuel transducer(s), perform the
following steps:
1. Record the level of the fuel in the tank(s).
2. Connect the portable tank(s) to the engine
through the fuel transducer(s).
16
Northstar Explorer 443d/443df Installation and Operation Manual
3. Run the engine at normal cruising speed
until at least 4 gallons (15 litres) of fuel has
been used per engine.
4. Check the actual amount of fuel used per
engine by refilling the portable tank(s) to
the original level and noting the reading(s)
from the fuel dispenser's gauge.
5. Select Fuel. Use the cursor keys to change
the reading for each engine to match that
on the fuel dispenser's gauge.
6. Press ENT when the reading is correct.
Note: If the fuel calibration options appear to
give erroneous readings after a while, first check
that the fuel sensor has been installed correctly
according to the installation instructions supplied
with it. Then see Appendix B - Troubleshooting.
Keel offset
Keel offset is a depth correction representing the
vertical distance between the depth transducer
and the location from which the depth is to be
measured.
Enter a positive keel offset value when the
transducer is located below the water surface but
the total depth is required.
Enter a negative keel offset value when the
depth below the deepest part of the boat is
required (such as the keel, the rudder or the
propeller) and the transducer is located closer to
the water surface.
Use the cursor keys to select Keel offset,
then press
to display the Keel offset box.
Use the
or
cursor keys to adjust the value.
Note: Boat illustrated uses a through hull transducer
Water surface
Positive
value
Depth of transducer
Negative
Transducer
value