Wine Guardian Pro DP200 Installation, Operation And Maintenance Manual

Wine Guardian Pro DP200 Installation, Operation And Maintenance Manual

Professional grade packaged cooling systems
Table of Contents

Advertisement

Quick Links

Ducted Systems
Professional Grade
Packaged Cooling Systems
Installation, Operation and Maintenance Manual
DP25, DP50, DP88, DP200
Manufactured by:
Syracuse, NY
www.wineguardian.com
www.airinnovations.com
Wine Guardian reserves the right, without notice, to make changes to this document at its sole discretion.
Please visit our web site for the most current version of the Wine Guardian PRO manual and other literature.
Wine Guardian is a registered trademark (2,972,262) of Air Innovations, Inc. Edition 01-2019 © Air Innovations 2019
Part No. 15H0167-00
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pro DP200 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Receiving and Initial Inspection
Unit Inspection and Verification
Procedures for inspecting the unit upon arrival and verifying the packing slip details.
Standard Specifications
Unit Components and Features
Lists the components and features included within the Wine Guardian PRO unit.
Safety Protocols and Warnings
Safety Message Conventions and Alerts
Defines DANGER, WARNING, CAUTION messages and general safety precautions.
Lockout/Tagout and General Safety
Procedures for safe isolation and general safety considerations for hazards.
Moving Parts, Interlocks, and Power Switch
Hazards of moving parts, safety interlocks, and main power switch operation.
Installation Procedures
Pre-installation Test and Preparation
Steps to test the unit before installation and prepare for the process.
Planning and Location Strategy
Planning the installation, performing checks, and deciding unit location.
Grilles, Noise Reduction, and Outdoor Installation
Installing grilles, reducing noise, and guidelines for outdoor placement.
Mounting and Drain Connection
Mounting Methods (Floor, Wall, Ceiling)
Instructions for floor, wall, and ceiling mounting, ensuring stability and levelness.
Condensate Drain Installation
Guidance on connecting the unit's condensate drain line for proper moisture removal.
Ductwork and Grille Installation
Ductwork Sizing and Grille Placement
Chart for duct sizing and guidance on locating supply/return grilles.
Ductwork Best Practices
Recommendations for supporting, stretching, and connecting ductwork for optimal performance.
Duct Adapter Sizes and Options
Single Outlet Duct Installation
Illustration of installing ductwork for a single supply air outlet.
Inspection and Start-up Procedures
Receiving and Initial Inspection Checklist
Checklist for initial unit inspection upon receipt.
Handling and Installation Checklist
Checklist for physical handling and installation preparation.
Start-up Verification Checklist
Checklist for verifying the unit's operation after installation.
System Start-up and Operation
Powering On and Fan Testing
Steps to power on the unit and test fan operation via thermostat settings.
Running the Unit and Initial Checks
Procedures for confirming unit operation and checking for normal performance.
Unit Cycling and Thermostat Settings
Understanding unit cycling and setting the thermostat for optimal control.
Regulating Temperature and Airflow
Tips for maintaining cellar temperature and adjusting airflow direction.
Maintenance Procedures
General Maintenance Safety
Safety warnings and general advice before performing maintenance tasks.
Cleaning Filters and Drain System
Steps for cleaning air filters and the condensate drain system.
Humidifier and Heating Coil Care
Instructions for optional humidifier maintenance and heating coil testing.
Low Ambient Feature and Maintenance Schedule
Explains low ambient operation and provides monthly/yearly maintenance tasks.
Troubleshooting Guide
Start-up and Power Issues
Diagnosing and resolving common start-up and power-related problems.
Temperature Control Problems
Solutions for issues related to cellar temperature being too cold or uncontrolled.
Humidity Control Problems
Solutions for problems related to cellar humidity being too low or too high.
Miscellaneous Operational Problems
Solutions for issues like no power light, water leaks, and objectionable noise.
High Pressure Switch Faults
Resetting the High Pressure Switch
Step-by-step guide to reset the high pressure switch to restore operation.
Advanced Troubleshooting
Coil Freezing, Switch Tripping, and Cycling
Diagnosing evaporator coil freezing, switch tripping, and unit cycling issues.
Noise, Vibration, and Blower Replacement
Troubleshooting noise/vibration and procedures for replacing blowers.
Warranty Information
General Warranty Terms and Liability
Outlines warranty period, liability limits, and exclusions for defects.
Indemnification and Legal Clauses
Purchaser's indemnification and other legal provisions of the warranty.
Contact and Warranty Procedures
Contact Information and Support
Provides contact details for Wine Guardian support and service.
Warranty Claim Procedure
Details on how to initiate warranty claims and required procedures.