Desa Design Dynamics VTD-18N-BTB Owner's Operation And Installation Manual page 16

Desa gas log vented decorative appliance owner's manual
Hide thumbs Also See for Design Dynamics VTD-18N-BTB:
Table of Contents

Advertisement

16
TROUBLESHOOTING
TROUBLESHOOTING
Continued
• Shut off gas supply.
• Do not try to light any ap pli ance.
• Do not touch any elec tri cal switch; do not use any phone in your
• Immediately call your gas sup plier from a neighbor's phone. Follow
• If you cannot reach your gas sup plier, call the fi re de part ment.
IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These
odors will disappear over time.
OBSERVED PROBLEM
Remote does not function (Remote-Ready
Models Only)
Appliance produces a click ing/tick ing noise
just after burners are lit or shut off
Appliance produces un wanted odors
Appliance shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
Gas odor during combustion
WARNING: If you smell gas
build ing.
the gas sup pli er's in struc tions.
POSSIBLE CAUSE
1. Battery is not installed. Battery power is
low
1. Metal expanding while heating or con-
tract ing while cooling
1. Appliance burning vapors from paint,
hair spray, glues, cleaners, chem i cals,
new carpet, etc. (See IM POR TANT
state ment above)
2. Low fuel supply (propane/LP only)
3. Gas leak. See Warn ing statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warn ing statement at
top of page
2. Control valve or gas control defective
1. Foreign matter be tween con trol valve and
burner
2. Gas leak. See Warn ing statement at
top of page
For more information, visit www.desatech.com
REMEDY
1. Replace 9-volt batteries in receiver and
remote control
1. This is common with most appliances. If
noise is excessive, contact quali fi ed ser vice
per son
1. Open window to ventilate room. Stop us ing
odor causing prod ucts while appliance is
running
2. Refi ll supply tank (propane/LP only)
3. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
1. Open window and/or door for ven ti la tion
2. Contact local natural or pro pane/LP gas
company
3. Clean ODS/pilot (see Cleaning and Main-
te nance, page 13)
1. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
2. Replace control valve or gas control
1. Take apart gas tubing and remove for eign
mat ter
2. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
111826-02F

Advertisement

Table of Contents
loading

Table of Contents