HP StorageWorks
2000 Modular Smart Array
Controller Module Replacement
Instructions
This document details procedures for replacing a failed
controller module in an HP StorageWorks 2012/2212
Modular Smart Array (MSA2000).
© Copyright 2008, 2010 Hewlett-Packard Development Company,
L.P.
Third edition: March 2010
The information in this document is subject to change without notice.
Printed in China.
www.hp.com
*488318-003*

About this document

Illustrations in this document may show a controller module with a
connection interface that differs from your controller module. Replace-
ment procedures are the same for all MSA2000 controller modules.
The Storage Management Utility (SMU) and the Command Line Inter-
face (CLI) can be used to manage MSA2000–family enclosures.
Tasks in this document demonstrate using the SMU.
For the latest product documentation, see the HP website at
www.hp.com/support/manuals. Under the storage banner, navigate
to the page for your storage enclosure.

Before you begin

Observe the following:
CAUTION:
When replacing a controller in an operational controller en-
closure, ensure that less than 10 seconds elapse between in-
serting the controller into a slot and fully latching it in place.
Failing to do so might cause the controller to fail. If it is not
latched within 10 seconds, remove the controller from the slot
and repeat the process.
Removing a module from an operational enclosure significantly
changes air flow within the enclosure. Openings must be
populated for the enclosure to cool properly. Leave modules
in the enclosure until a replacement is available.
Parts can be damaged by electrostatic discharge; use proper
anti-static protection. Keep parts in electrostatic containers
until needed and ensure you are properly grounded when
touching static-sensitive components.
IMPORTANT:
When replacing both controllers in an operational enclosure,
do as follows:
1.
Replace one controller as detailed in these instructions.
2.
Wait 30 minutes. This pause ensures that the two controllers
and their ownership of the vdisks have enough time to fully
stabilize.
3.
Examine system status and event logs to ensure that the system
is stable.
4.
Replace the other controller as detailed in these instructions.
IMPORTANT:
When two controllers are installed in an enclosure, they must
be the same model. Mixing controller types in the same
enclosure is not supported.
Page 1
http://

Advertisement

loading

Summary of Contents for HP 2000fc

  • Page 1: About This Document

    Parts can be damaged by electrostatic discharge; use proper anti-static protection. Keep parts in electrostatic containers until needed and ensure you are properly grounded when © Copyright 2008, 2010 Hewlett-Packard Development Company, touching static-sensitive components. L.P. Third edition: March 2010 The information in this document is subject to change without notice.
  • Page 2 NOTE: Enabling Partner Firmware Upgrade To reduce impact on system performance, perform all (dual-controller configurations only) maintenance tasks during periods of low system activity or during a system maintenance window. In a dual-controller configuration, the Partner Firmware Upgrade option ensures that both controllers have the most recent version. HP recommends enabling this feature.
  • Page 3 Turn the thumbscrews until the screws disengage from the module. Installing the new module With the latches in the open position, slide the module into the enclosure as far as it will go (1). If necessary, press lightly on the top-center of the module to facilitate insertion.
  • Page 4: Verifying The Firmware Version

    Verifying configuration settings After replacing a controller, verify that system configuration settings are set properly for your environment. Repeat the commands shown in “Recording configuration settings” on page 2 and compare the current values with those recorded before the installation. If necessary, change the settings to their previous values.