CLEANING AND MAINTENANCE

26
Glass Door
Pilot and Burners
Logs
Venting System
CLEANING AND
MAINTENANCE
WARNING: Turn off fireplace and let cool before
cleaning.
CAUTION: You must keep control areas, burners,
and circulating air passageways of fireplace clean.
Inspect these areas of fireplace before each use.
Have fireplace inspected yearly by a qualified service
person. Fireplace may need more frequent cleaning
due to excessive lint from carpeting, bedding mate-
rial, pet hair, etc.
GLASS DOOR
WARNING: Handle glass door panel with care. Do
not strike, slam, or otherwise abuse glass. Do not
operate fireplace with the glass door removed,
cracked, or broken.
WARNING: Do not use abrasive cleaners as this
may damage glass. Use a nonabrasive household glass
cleaner to clean glass. Do not clean glass when hot.
Glass must be cleaned periodically. During start-up it is normal for
condensation to form on the inside of the glass causing lint, dust, and
other airborne particles to cling to the glass surface. During initial
start-up a slight film may form on the glass due to paint curing. The
glass should be cleaned several times with a non-ammonia, nonabra-
sive household cleaner and warm water after the first two weeks of
operation. Thereafter, clean the glass two or three times during each
heating season, depending on the usage and circumstances present.
Refer to Removing/Replacing Glass Door on pages 20 and 21 of this
manual when removing glass door for cleaning.
WARNING: Only parts supplied by the manufac-
turer should be used when replacing broken or dam-
aged glass door panel (see Replacement Parts , page
29). This glass door panel is a complete unit. No
substitute materials may be used.
CAUTION: Wear gloves and safety glasses while
handling or removing broken glass. Do not remove if
glass is hot. Keep children and pets away from glass.
If glass has been broken, carefully remove glass door (see Remov-
ing/Replacing Glass Door, pages 20 and 21). Vacuum all glass
pieces with a shop vac.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
CAUTION: Do not vacuum if pieces are hot.
Use only the tempered glass door replacement intended for this
fireplace (see Replacement Parts, page 30 for detail on ordering).
No substitutions may be made. See Removing/Replacing Glass
Door, pages 20 and 21 for instructions for replacing glass door.
WARNING: Do not operate fireplace with the glass
door removed, cracked, or broken.
PILOT AND BURNERS
• Remove ember material before cleaning burners and replace
when cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove
excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, Lava
Rock, and Glowing Embers, page 22, to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See Replacement Parts on page 29.
• Replace ember material periodically as needed. See Replace-
ment Parts on page 29.
VENTING SYSTEM
Conduct annual inspection of the venting system following these
guidelines:
1.
Check areas of venting system that are exposed to the weather for
corrosion (rust spots or streaks and, in extreme cases, holes). Have
these items replaced immediately by a qualified service person.
2. Remove the vent cap and shine a flashlight into the vent. Re-
move any foreign material.
3. Check for evidence of excessive condensation. Continuous
condensation can cause corrosion of caps, pipes, and fittings
and can be caused by having excessive lateral runs, too many
elbows, or exterior portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section or fitting has been
disturbed and loosened. Check mechanical supports such as
wall straps for rigidity.
111924-01A