FIREPLACE INSTALLATION
Continued
4. Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.
5. Mount speed control box to switch bracket by placing the plastic
control shaft forward through the opening in the switch bracket
(see Figure 26).
6. While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise until it
is tight against front panel. Place control knob provided on shaft.
7. Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 16.
8. Plug in blower power cord.
a. If your firebox is installed as a freestanding unit with an
accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Route power
cord through exit hole and plug the power cord into a wall
receptacle near the firebox.
b. If your firebox installation is recessed and/or pre-wired,
plug the power cord into the duplex outlet provided. Refer
to your firebox owner's manual for instructions on wiring
the duplex outlet.
CAUTION: Never touch the blower wheel while in
operation.
9. Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Turn blower on and check for operation. Turn blower off
by turning knob fully counterclockwise before continuing.
10. Peel off the backing paper and stick the supplied wiring dia-
gram decal on the firebox bottom approximately 12" in front
of the blower (see Figure 27).
Switch
Bracket
Control
Knob
Locknut
Figure 26 - Attaching Speed Control to Firebox
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111924-01A
Speed Control
Blower
Plug-In
Control
Duplex Outlet
Shaft
(Located underneath
firebox floor against
lower right outside wall)
FIREPLACE INSTALLATION
Installing Optional Blower Accessory (Cont.)
Wiring Diagram Decal
12" in Front of Blower
Figure 27 - Location of Wiring Diagram Decal (Model May Vary
From Illustration)
Model BKT Installation
Note: When installing the BKT thermostatically-controlled blower,
you must first secure the thermal switch bracket to the blower if it
has not already been factory installed.
1. Place the green ground wire with ring terminal between the
bottom hole on the thermal switch bracket and the top ear hole
on the blower assembly. Insert the phillips screw into all three
pieces and tighten securely (see Figure 28).
2. Connect wire harness and power cord terminals. Connect the
blue jumper wire to the blower motor terminal and the right
side terminal of the thermal switch. Connect the black wire to
the left side of the thermal switch and the white wire to the
other remaining blower motor terminal.
Note: The power cord outer insulation sleeve may have to be
stripped slightly to allow enough wire length to reach and make all
connections. DO NOT trim excessive length away. Just enable
enough to make all connections securely.
Power Cord
Thermal
Switch
Bracket
Black
Wire
Phillips
Screw
Thermal Switch
Route BKT
Blower Through
This Area
Side View Firebox Bottom
Figure 28 - Blower Model BKT
White Wire
Blue Wire
Magnetic
Strips
Air Flow
Direction
Ring Terminal
on Green Wire
Air Flow Direction
Thermodisc
17
17
Magnets
Blower
Location