Cleaning And Maintenance - Desa CHL3924NR Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: you must keep con-
trol areas, burners and circulating
air passageways of heater clean.
Inspect these areas of heater
before each use. Have heater
inspected yearly by a qualified
service person. Heater may need
more frequent cleaning due to
excessive lint from carpeting, pet
hair, bedding material, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
BURNER INjECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean
burning flame. Keep these holes clear of dust, dirt,
lint and pet hair. Clean these air inlet holes prior to
each heating season. Blocked air holes will create
soot. We recommend that you clean the unit every
three months during operation and have heater
inspected yearly by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store or home center
may carry compressed air in a can. You can use a
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on
the can. If you don't follow directions on the can,
you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet holes on
injector holder for dust and dirt (see Figure 38).
3. Blow air through the ports/slots and holes in
the burner.
111161-01H
4. Check the injector holder located at the end
of the burner tube again. Remove any large
particles of dust, dirt, lint or pet hair with a
soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
2" from where the pilot flame comes out of the
pilot assembly (see Figure 39). With the unit off,
lightly blow air through the air inlet hole. You may
blow through a drinking straw if compressed air
is not available.
Burner
Tube
Figure 38 - Injector Holder On Outlet
Burner
Tube
Pilot Assembly
Pilot Air
Inlet Hole
LOGS
• If you remove logs for cleaning, refer to Install-
ing Logs, page 17, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
MAIN BURNER
Periodically inspect all burner flame holes with the
heater running. All slotted burner flame holes should
be open with yellow flame present. All round burner
flame holes should be open with a small blue flame
present. Some burner flame holes may become
blocked by debris or rust, with no flame present. If
so, turn off heater and let cool. Remove blockage.
Blocked burner flame holes will create soot.
www.desatech.com
Primary Air
Inlet Holes
Burner Tube
Figure 39 - Pilot Inlet Air Hole
Injector
Holder
Ports/Slots
3