Download Print this page
Annovi Reverberi BHS 105 Instruction Manual

Annovi Reverberi BHS 105 Instruction Manual

550 rpm - semi-hydraulic four diaphragm pump

Advertisement

Quick Links

140° F - Max Water Temp
1 1/2" - Suction
3/4" BSP - Outlet
BHS90 • BHS105 • BHS120 - 550
m
odeL
BHS90-C/C
BHS105-C/C
BHS120-C/C
d
K
iAPHRAgm
iTS
m
d
odeL
eScRiPTion
AR43317
BlueFlex
AR43315
Desmopan
AR43314
NBR
AR43316
Viton
INSTRUCTION MANUAL
RPm
m
gPm m
L/m
Ax
Ax
23.9
90.6
26.9
101.9
29.8
113.0
V
K
ALVe
iTS
m
d
odeL
eScRiPTion
AR2445
Valves
- S
-H
emi
ydRAuLic
m
PSi
m
B
in
Ax
Ax
725
50
725
50
725
50
o-R
K
ing
iTS
m
d
odeL
eScRiPTion
AR42205
O-Rings
BHS
BHS 105
BHS 120
F
d
ouR
iAPHRAgm
w
eigHT
HP P
L
AR
oweR
BS
10.5
94.4
12.0
94.4
13.3
94.4
o
iL
m
odeL
AR64532D
AR64532D-C Case (6)Oil
90
P
umP
.
d
eScRiPTion
Oil

Advertisement

loading
Need help?

Need help?

Do you have a question about the BHS 105 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Safety Information
Intended Uses
The pump is designed for agricultural spraying machines. All other uses constitute misuse.
Prohibited Uses (Misuses)
Lists prohibited uses like explosive atmospheres, flammable liquids, and high temperatures.
Safety Devices
Emphasizes not tampering with safety devices and performing regular maintenance.
Residual Risks
Notes that residual risks apply even if safety regulations are followed.
Installation Instructions
Installation Diagram
A simplified illustration of the typical installation layout for the pump system.
Water Supply Connection Guidelines
Details on drawing liquids from containers at atmospheric pressure and avoiding pressurised liquids.
General Installation Details
Details on crankshaft rotation, water connection hoses, and inlet filter requirements.
Pump Mounting
Guidance on pump installation surface, angle limits, and bolting procedures.
Handling and Transport Instructions
Handling and Lifting Safety
Procedures for safe lifting, handling, and unloading by skilled staff.
Packaging and Unpacking
Information on packaging, checking contents, and disposal of packaging materials.
Transport and Storage
Guidelines for securing the pump during transport and storing it when not in use.
Installation Safety Recommendations
Precautions for safe installation, considering mounting points and energy sources.
Instructions for Use
Usage Safety Recommendations
Pre-start checks, leak management, and operating limits.
Preliminary Operational Checks
Steps for checking inflation pressure, fittings, and oil level before operation.
Starting and Stopping Procedure
Procedures for safely starting and stopping the pump, including priming and bypass use.
Maintenance Instructions
Maintenance Safety Precautions
Precautions before maintenance, isolation from energy sources, and component replacement.
Scheduled Maintenance
Details frequency, components, procedures, and references for daily and periodic checks.
Lubricant Recommendations
Information on the recommended oil for the pump.
Pump Mounting Inspection
Checking and tightening the pump's fixing screws.
Connections and Pipes Inspection
Checking for leaks and inspecting hoses for aging or damage.
Inlet Filter Inspection
Guidance on inspecting, cleaning, or replacing the inlet filter cartridge.
Oil Level Check
Procedure for checking and topping up the pump's oil level.
Pump Storage Procedures
Recommendations for flushing and preparing the pump for storage, including winterization.
Returning Pump to Service
Checks required before restarting the pump after storage.
Pump Scrapping
Disposal of used units according to local legislation.
Troubleshooting Guide
Pump Priming Issues
Addresses causes and remedies for the pump not priming properly.
Pressure Output Problems
Covers issues with achieving required pressure due to worn parts or restrictions.
Pulsating Pressure
Solutions for pressure gauge needle wobbling and pulsating pressure.
Uneven Liquid Flow
Addresses causes and remedies for uneven flow of liquid to nozzles.
Cavitation and Noise
Explains causes of cavitation, noise, and oil level drops.
Oil Leaks and Contamination
Addresses oil on the pump body or emulsion in the oil tank.