Desa AMITY SDVBPD Owner's Operation And Installation Manual page 15

Cast iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

VENTING INSTALLATION
Continued
Horizontal Termination Configurations
Figures 28 through 30 show different configurations for venting
with horizontal termination. Each figure includes a chart with
vertical minimum/maximum and horizontal maximum dimensions
which must be met. Seal all connections with high temperature
silicone sealant (outer pipe only) as specified in the second warning
statement on page 12. All horizontal piping runs require 1/4" rise per
12" of horizontal run.
Horizontal Venting
Vertical (V) Horizontal (H)
52" min.
26" max.
63" min.
49" max.
86" min.
96" max.
91" min.
20' max.
Figure 28 - Horizontal Termination Configuration for Venting
°
Using One 90
Elbow
For more information, visit www.desatech.com
For more information, visit www.desatech.com
112126-01B
VENTING INSTALLATION
Installation for Horizontal Termination (Cont.)
Venting with Three 90
Vertical (V) Horizontal (H
6' min.
4' max.
7' min.
6' max.
8' min.
8' min.
20' max.
8' max.
Figure 29 - Horizontal Termination Configuration for Venting
°
Using Three 90
Elbows
Venting with Two 90
°
Vertical (V)
Horizontal (H
Horizontal (H
6' min.
4' max.
7' min.
6' max.
8' min.
10' max.
20' max.
12' max.
Figure 30 - Horizontal Termination Configuration for Venting
°
Using Two 90
Elbows with Termination at 90
°
Elbows
) Horizontal (H
) +
1
1
Horizontal (H
)
2
8' max.
12' max.
20' max.
20' max.
Elbows
) +
1
)
2
°
with Stove
15
15

Advertisement

Table of Contents
loading