Technical Data Europe Version L07Rs - CompAir L11RS Operating And Service Manual

Table of Contents

Advertisement

11. Annex

11.3 Technical data EUROPE version L07RS

Technical data 50Hz / 60Hz
Maximum operating pressure
Minimum operating pressure
Ambient temperature
Operating pressure
Flow
After-cooler outlet temperature above ambient temp.
Sound pressure level (to ISO 2151)
Nominal motor rating
Voltage (frequency)
Full-load current max. (380V/400V/460V)
Motor protection type
Nominal speed
Nominal fan motor power
Recommended cable cross-section (380V/400V/460V) mm
Recommended fuse size (380V/400V/460V)
Cooling air flow through ventilator
Cooling air outlet temperature above ambient temp.
Max. allowable pressure drop in duct at ambient
35°C/45°C
Total oil volume
Compressed air delivery connections
Weight
Dimensions L x W x H
bar
bar
°C
bar
7.5 bar
min.
max.
min.
3
m
/min
0.48
1.26
0.46
°C
dB(A)
kW
380V[+10% -5%];400V[+/-10%]; 460V[+/-10%]
V
A
rpm
kW
2
A
3
m
/min
°C
Pa
l
---
EN 10226 Rp 3/4" (DIN 2999-Rp 3/4)
kg
mm
L07RS
13.0
5.0
+ 1 / + 45
9 bar
10 bar
max.
min.
max.
1.10
0.44
1.01
13
69
7,5
(50, 60Hz)
22 /21 /18
IP55, IE 2
1256...2950
no separate fan motor
4G4 /4G4 /4G4
25 / 25 / 20
25
18
110 / 90
5
222
667 x 630 x 1050
13 bar
min.
max.
0.41
0.83
55