OPERATING FIREPLACE
26
Optional Hand-Held Remote Operation
OPERATING FIREPLACE
Continued
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, page 37). Follow instructions included
with the remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on page 25.
After lighting, let pilot flame burn for about one minute. Turn
control knob to ON position. Adjust flame adjustment knob
anywhere between HI and LO. Slide the selector switch to the
REMOTE position (see Figure 52). Note: The burner may light
if hand-held remote was on when selector switch was last turned
off. You can now turn the burner on and off with the hand-held
remote control unit.
IMPORTANT: Do not leave the selector switch in the REMOTE
or ON position when the pilot is not lit. This will drain the
battery.
Blower Control Knob
(Optional Accessory)
Selector Switch
in Remote
Position
Figure 52 - Setting the Selector Switch, Gas Control Knob, and
Variable Control Knob for Remote Operation
ON/OFF SERIES (MODEL GHRCB)
Hold the control button on the hand-held remote until burner
turns on. Hold the control button again until burner turns off
(see Figure 53).
TO LOCK press both buttons on hand-held remote control until
light stops flashing. Hand-held remote control is now locked. If
the fire is on it will be turned off automatically. In the locked
state, the light will not light up when any button is pressed.
TO UNLOCK press both buttons together on hand-held remote
control until the light stops flashing. The hand-held remote is
now unlocked.
Figure 53 - On/Off Hand-Held Remote Control Unit (GHRCB)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Variable
Control Knob
OFF
ON
Gas Control Knob
in ON Position
Control Button
Turns Burners
On and Off
THERMOSTAT SERIES (MODEL GHRCTB)
The hand-held remote can be operated using either the manual
mode (MANU) or thermostatic mode (AUTO) (see Figure 54).
To select Fahrenheit/Centigrade mode display, carefully press
the ˚C/˚F mode button with the end of a paper clip or similar
blunt object.
Manual Mode
1. Press the POWER and LOCK buttons together to turn on
the hand-held remote control.
2. Press the MANU button to turn on the fireplace.
3. Press the POWER and LOCK buttons together to turn off
the fireplace.
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons together to turn on
the hand-held remote control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by pressing the TEMP +
or - buttons.
4. Press the POWER and LOCK buttons together to turn off
the fireplace
Note: Do not leave the hand-held remote in the AUTO mode
close to the fireplace. The radiant heat from the fireplace will
turn off the fireplace. Ideally, place the hand-held remote in the
center of the room facing towards the fireplace.
Note: Do not hold the hand-held remote for a long time. Body
temperature will affect its operation in the AUTO mode.
Digital Display
Shows
Temperature and
Settings
Turns Burners
On or Off
Decreases Room
Temperature in
AUTO Mode
Figure 54 - Thermostat Hand-Held Remote Control Unit (GHRCTB)
Safety Features
When away from home for an extended period of time or as a
child safety feature to prevent accidental ignition of the fire-
place, the receiver ON/OFF/REMOTE switch should be in the
OFF position.
Turns Hand-Held
Remote On or Off and
Allows You to Choose
the Manual Setting
Selects Auto Setting
Increases Room
Temperature in AUTO
Mode
Locks System to
Prevent Accidental
Ignition
111250-01C

Advertisement

Table of Contents
loading