Finish Mounting; Specifications - Desa JourneyMan HD-9260 User Manual

Journeyman series all metal motion sensor quartz light control
Table of Contents

Advertisement

Available languages

Available languages

Finish Mounting

Align the JourneyMan
the junction box holes. Secure with mounting
screws that fit your junction box.
If not installed on a weatherproof box or if the
adaptor plate was used, caulk between the
base plate and mounting surface with sili-
cone weather sealant.
• Allow fixture to cool before touching. The bulb and the fixture
operate at high temperatures.
• Keep fixture at least 3" (76 mm) from combustible materials.
Do not aim at objects closer than 3' (1 m).
• Use only type T 250W (max.) tungsten halogen 120 VAC lamps.
®
base plate, gasket, and
To obtain maximum lamp
life, keep the tubular
lamps horizontal.
CAUTION: To Avoid Fire Or Burn Hazards:

Specifications

Range .............................. Up to 100 feet (30.5 m) with
Sensing Angle ................. Up to 270°
Fixture Load ................... 500 watts max., Incandescent
Sensor Load Capacity ..... 1000 watts (8.3 amps), In-
Power Requirements ....... 120 VAC, 60 Hz
Operating Modes ............ TEST, AUTO and MANUAL
Time Delay ..................... 1 , 5, 20 minutes
Sensitivity ....................... Adjustable
-8-
Range Boost On; up to 70
feet (21 m) with Range
Boost Off. (Varies with sur-
rounding temperature).
(250W each lamp holder)
candescent
MODE
598-1007-02