Desa 10542 Safety Information And Installation Manual page 8

Unvented (vent-free) blue flame gas heater
Hide thumbs Also See for 10542:
Table of Contents

Advertisement

INSTALLATION
Continued
INSTALLATION ITEMS
Before installing heater, make sure you have the
items listed below.
• for propane/LP gas, external regulator (supplied
by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. The optional CSA design-
certified equipment shutoff valve can be purchased
from your dealer. See Accessories, page 30.
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the
minimum clearances shown in
Figure 4. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
You can locate heater on floor, away from a wall.
An optional floor mounting stand is needed. Pur-
chase the floor mounting stand from your dealer.
See Accessories, page 30.
WARNING: Never install the
heater
• in a bathroom
• 20,000 or 30,000 Btu in a bed-
room
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
8
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.)
in the air exist, may discolor
walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to the
air. Although this is beneficial, installing heater in
rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air for
Combustion and Ventilation, page 5. If high humid-
ity is experienced, a dehumidifier may be used to
help lower the water vapor content in the air.
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18 inches above
floor
• locate heater where moving
vehicle will not hit it
For convenience and efficiency, install heater
• where there is easy access for operation, inspec-
tion, and service
• in coldest part of room
An optional fan kit is available from your dealer.
See Accessories, page 30. If planning to use fan,
locate heater near an electrical outlet.
Minimum
From
Sides Of
Heater
Left
Side
Figure 4 - Mounting Clearances As
www.desatech.com
CAUTION: This heater cre-
CEILING
6"
FLOOR
Viewed From Front of Heater
36"
Minimum
Right
Side
Minimum To
Top Surface
Of Carpeting,
2"
Tile Or Other
Combustible
Material
113680-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

105431054410545105461054710548 ... Show all

Table of Contents