PV SYSTEM CONTROLLERS
Te m p e r a t u re Setpoints
High Te m p e r a t u re Shutdown:
Disconnect PV:
Disconnect Load:
Reconnect PV:
Reconnect Load:
Operating Te m p e r a t u re Range:
Te m p e r a t u re Compensation Coeff i c i e n t :
Cold Te m p e r a t u re Load Cutoff :
Reconnect of Cold Te m p e r a t u re Load Cutoff :
C o n t rol Setpoints
High Battery Voltage System
Shutdown (8 seconds):
Reset For High Voltage Shutdown (I n s t a n t l y):
B a t t e ry Equalization:
Regulation Vo l t a g e :
B a t t e ry LVD Voltage (32 seconds):
Load Reconnect After Low Voltage
Disconnect (LVD) ( I n s t a n t l y ):
Automatic equalization:
Equalization can be triggered (32 seconds):
(24V set points are twice the 12V values)
M i c ro p rocessor Sampling Period
PV Voltage Sampling:
B a t t e ry Voltage Sampling:
Te m p e r a t u re Sampling:
Load Current Sampling
After Over- C u rrent Sampling:
Other Specifications
Weight:
D i m e n s i o n s :
Load Short Circuit Rating:
Meter Accuracy:
7812 EAST ACOMA DRIVE
SCOTTSDALE, AZ 85260 USA
480/951-6330 • 800/544-6466
FAX: 480/951-6329
www.kyocerasolar.com
e-mail: info@kyocerasolar.com
7 0 ° C
8 0 ° C
6 0 ° C
5 0 ° C
-40°C to +80°C
- 2 5 m V / C e l l / C °
- 3 0 ° C
- 3 0 ° C
S e a l e d
B a t t e ry
15.5 V
14.5 V
14.1 V
11.3 V
12.8 V
8 seconds
Constantly
3 seconds
3 - 6 seconds
(All ratings at 25°C)
7 oz. (.2 kg)
5.7 x 2.6 x 2.1 in. (14.48 x 6.6 x 5.33 cm)
15 Amps -PV12M
2% - PV12M
F l o o d e d
B a t t e ry
15.5 V
14.5 V
15.3 V
14.4 V
11.4 V
13.0 V
14 days
V < 1 1 . 4 V