OPERATING HEATER
Continued
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, page
15, column 2.
2. Make sure equipment shutoff valve is fully
open.
3. Turn thermostat control knob clockwise
to the OFF position (see Figure 22
or 23 for your model).
4. Wait five minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information, page 15, column 2. If you donʼt
smell gas, go to the next step.
5. Turn thermostat control knob counter-
clockwise
Press in thermostat control knob for 5 sec-
onds (see Figure 22 or 23 for your model).
Note: You may be running this heater for
the first time after hooking up to gas supply.
If so, you may need to press in thermostat
control knob for 30 seconds or more. This
will allow air to bleed from the gas system.
If thermostat control knob does not pop
up when released, contact a qualified ser-
vice person or gas supplier for repairs.
6. Keep thermostat control knob pressed in while
pushing down and releasing the ignitor button.
This will light pilot. If necessary, continue to
press ignitor button until pilot lights.
If pilot does not light
turn thermostat control knob clockwise
to the OFF position
repeat steps 5 and 6
If pilot does not stay lit after several tries
refer to Troubleshooting, page 20
contact a qualified service person or gas
supplier
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, page 17.
7. Keep thermostat control knob pressed in
for 30 seconds after lighting pilot. After 30
seconds, release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety interlock
system. Wait one minute before lighting
pilot again.
16
to the PILOT position.
www.desatech.com
8. Turn thermostat control knob counter-
clockwise
level. For models, VP16TA, VN18TA,
VP26TA and VN30TA, the main burner
should light. Set control knob to any heat
level between 1 and 5 (see Figure 25). For
infrastat models, the plaque directly above
the pilot should light.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor Button
Figure 22 - Control Knob In The OFF
Position, Models VP16TA, VN18TA,
VP26TA, & VN30TA
Figure 24 - Pilot
Control
VP16TA
Knob
VN18TA
Figure 25 - Burner Patterns
to the desired heating
Control Knob
Thermocouple
Ignitor Electrode
Pilot Burner
VP26TA
VN30TA
113052-01D