® VENT-FREE NATURAL GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUAL Models: VN1000BA & VN600B WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
Service Hints ................. 24 Replacement Parts ................. 25 Service Publications ..............25 Accessory ..................25 Illustrated Parts Breakdown (Model VN1000BA) ......26 Parts List (Model VN1000BA) ............. 27 Illustrated Parts Breakdown (Model VN600B) ......28 Parts List (Model VN600B) ............29 Warranty Information ..............
Page 3
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the fire department 3. Heater model VN1000BA shall not be installed in a bathroom. 4. Never install the heater • in a recreational vehicle •...
Cabinet Panel Figure 1 - Vent-Free Natural Gas Heater (Model VN1000BA Shown) LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1 also known as NFPA 54*.
FRESH AIR WARNING WARNING ICON G 001 This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to COMBUSTION insure proper fresh air for this and other fuel-burning appliances in your home. VENTILATION Today’s homes are built more energy efficient than ever.
Page 6
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION FRESH AIR Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. COMBUSTION Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Page 7
FRESH AIR VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an COMBUSTION adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2).
Page 8
FRESH AIR VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- COMBUSTION nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
WARNING ICON G 001 Never install the heater • in a bathroom (Model VN1000BA - Input 10,000 BTUs) • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater •...
Page 10
INSTALLING For convenience and efficiency, install heater • where there is easy access for operation, inspection, and service TO WALL • in coldest part of room Continued CEILING 36" Minimum 6" Minimum From Sides Of Heater Right Side Left Side 3"...
Page 11
INSTALLING Installing Two Mounting Screws Wall anchors and mounting screws are in hardware package. The hardware Note: TO WALL package is provided with heater. Continued Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2.
Page 12
INSTALLING Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 9). TO WALL 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots. Continued Keyhole Slots Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater...
CONNECTING NOTICE TO GAS A qualified service person must connect heater to gas supply. Follow all local codes. SUPPLY WARNING WARNING ICON G 001 Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas. Check gas line pressure before connecting heater to gas line.
CONNECTING Hold pressure regulator with wrench when connecting it to gas piping IMPORTANT: and/or fittings. TO GAS SUPPLY Continued Pressure Regulator 3/8" NPT Pipe Nipple Heater Cabinet Ground Joint Union Tee Joint Manual Shutoff Reducer Test Valve * Bushing to Gauge From 1/8"...
Page 15
CONNECTING 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. TO GAS 5. Correct all leaks at once. SUPPLY Test Pressures Equal To or Less Than 1/2 PSIG Continued 1.
OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING HEATER WARNING WARNING ICON G 001 If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
Page 17
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including OPERATING near the floor. If you smell gas, STOP! Follow "B" in the safety information HEATER at the top of page 16. If you don’t smell gas, go to the next step. Continued 5.
OPERATING TO TURN OFF GAS TO APPLIANCE HEATER Shutting Off Heater 1. Turn control knob clockwise to the PILOT position. Clockwise Continued 2. Press in control knob and turn clockwise to the OFF position. Clockwise Shutting Off Burner Only (pilot stays lit) 1.
Page 19
Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame. 1/2 GLASS HEIGHT (Model VN1000BA) CORRECT FLAME PATTERN AT HIGH POSITION (Model VN600B will be lower due to lower input rating)
CLEANING WARNING WARNING ICON G 001 Turn off heater and let cool before cleaning. MAINTENANCE CAUTION WARNING ICON G 001 You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person.
Page 21
TROUBLE- POSSIBLE OBSERVED REMEDY CAUSE PROBLEM SHOOTING 1. Turn on gas supply or 1. Gas supply turned off When ignitor button Continued open manual shutoff or manual shutoff is pressed, there is valve spark at ODS/pilot valve closed 2. Turn control knob to but no ignition 2.
Page 22
TROUBLE- OBSERVED POSSIBLE PROBLEM CAUSE REMEDY SHOOTING Burner does not light 1. Burner orifice is 1. Clean burner orifice (see Continued after ODS/pilot is lit clogged Cleaning and Mainte- nance, page 20) or replace burner orifice 2. Burner orifice diameter 2.
Page 23
TROUBLE- WARNING WARNING ICON G 001 SHOOTING If you smell gas • Shut off gas supply. Continued • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. •...
TECHNICAL You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- SERVICE 5190. VN600B VN1000BA SPECIFICATIONS 4,400/6,000 BTU (Variable) 5,000/10,000 Natural Only Type Gas Natural Only Piezo Ignition Piezo 3" W.C.
REPLACEMENT Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.
This list contains replaceable parts used in your heater. When ordering parts, follow PARTS LIST the instructions listed under Replacement Parts on page 25 of this manual. VN1000BA PART NUMBER DESCRIPTION QTY. 098304-01 Screw, #10 x 3/8" 099467-03 Front Panel Assembly...
This list contains replaceable parts used in your heater. When ordering parts, follow PARTS LIST the instructions listed under Replacement Parts on page 25 of this manual. VN600B PART NUMBER DESCRIPTION QTY. 098304-01 Screw, #10 x 3/8" 099467-03 Front Panel Assembly 099318-04 Grill Guard 098342-01...
We make no other warranty, expressed or implied. LIMITED WARRANTY VANGUARD VENT-FREE NATURAL GAS HEATERS DESA International warrants this product and any parts thereof, to be free from defects in material and work- manship for two years from the date of first purchase, provided that the product has been properly installed, operated, and maintained in accordance with all applicable instructions.