Purpose of this guide This guide contains information regarding the installation and safe handling of Wuxi Suntech Power Co., Ltd photovoltaic module (hereinafter referred to as “module”). Wuxi Suntech Power Co., Ltd referred to as “Suntech”. Installers must read and understand this guide prior to installation. For any questions, please contact Suntech's Global Quality &...
appropriate protective equipment. When storing uninstalled modules outdoors for any period of time, always cover the modules and ensure that the glass faces down on a soft flat surface to prevent water from collecting inside the module and causing damage to exposed connectors. Purpose of this guide Installation safety Never disconnect electrical connections or unplug connectors while the circuit is under load.
Select the proper installation method depending on the load(See below for more detailed information). All installation methods herein are only for reference, and Suntech will not provide related mounting components. The system installer or trained professional personnel must be responsible for the PV system's design, installation, and mechanical load calculation and security of the system.
Page 7
72/V Series (Half cell solar module) 2000 mm × 992 mm × 35 mm 78/V Series (Half cell solar module) 2166 mm × 992 mm × 35 mm Suntech Standard Module Type Module Dimension (using 158.75 mm solar cell) Length × Width × Thickness A16/T (Half cell solar module) 1354 mm ×...
Page 8
Test load: 60/W Series positive 5400Pa A20/W Series negative 2400Pa A21/W Series 4 bolts installation Design load: A60/W Series positive 3600Pa B60/W Series negative 1600Pa Safety factor: 1.5 20/W Series Test load: positive 2400Pa 60/W Series negative 2400Pa A16/T Series 4 bolts installation Design load: A20/W Series...
Page 9
Test load: 20/W Series positive 5400Pa 60/W Series negative 3800Pa A20/W Series 8 bolts installation Design load: A21/W Series positive 3600Pa A60/W Series negative 2533Pa Safety factor: 1.5 16/T Series Test load: 20/W Series positive 2400Pa 24/V Series negative 2400Pa 60/W Series 4 clamps installation Design load:...
Page 10
60/W Series 72/V Series 78/V Series Test load: positive 5400Pa A20/W Series negative 3800Pa A21/W Series Design load: A60/W Series 4 clamps installation positive 3600Pa 21/W series L = 220 mm B60/W Series 60/W series L = 200 mm negative 2533Pa A72/V Series 72/V series L = 300 mm Safety factor: 1.5...
Page 11
16/T Series 20/W Series 24/V Series Test load: 60/W Series positive 5400Pa 72/V Series negative 3800Pa 6 clamps installation 78/V Series Design load: A16/T Series positive 3600Pa A20/W Series negative 2533Pa A21/W Series Safety factor: 1.5 A60/W Series A72/V Series Clamp zone: A = 1/4 short frame length ±50 mm = 100 mm...
Page 12
2) Customized mounting method Note: The test mechanical load value are based on Suntech internal test results with specific clamps. Mechanical load** Note: The installation Mounting method* Installation location Module type method is based on the internal results in Suntech.
24/V Series Test load: 72/V Series positive 2400Pa 78/V Series negative 2400Pa 4 clamps mixed A24/V Series Design load: mounting A72/V Series positive 1600Pa A78/V Series negative 1600Pa B72/V Series Safety factor: 1.5 A≥40mm; A0=1/4 short frame length±50mm; A1=360~560mm * The module clamps must not come into contact with the front glass or deform the frame in any way. Avoid shading effects from the module clamps and insertion systems.
Page 14
Parallel wiring Figure 1: Electrical diagrams of series and parallel wiring. The maximum number of Modules that can be connected in series within a string must be calculated in accordance with applicable regulations in such a way that the specified maximum system voltage (The maximum system voltage of bifacial module is DC 1500V) of the modules and all other electrical DC components will not be exceeded in open-circuit operation at the lowest temperature expected at the PV system location.
The maximum number of series connected modules depends on system design, the type of inverter used and environmental conditions. Based on the maximum series fuse rating of module and local electrical installation code, always make sure Suntech PV modules are assembled with the appropriate string fuse for circuit protection.
For grounding, this guide refers to module frame grounding. If grounding is required, make sure module frames (metal exposed to touch) are always grounded. Suntech recommends always refer to local state and national code requirements for PV module grounding. Suntech highly recommends negative grounding if it's allowed by local authorities.
For more information, please contact supplier: Schletter, http://www.solar.schletter.eu Maintenance To ensure optimum module performance, Suntech recommends the following maintenance measures: Clean the module minimum once a year or more often when required depending of the pollution. Remove all organic from the surface.
Page 22
尚德组件型号 组件尺寸(长×宽×厚) (使用156.75 - 157.4 mm电池片) 16/T系列(全片组件) 1324 mm × 992 mm × 35 mm 1640 mm × 992 mm × 35 mm 20/W系列(全片组件) 1650 mm × 992 mm × 35 mm 1956 mm × 992 mm × 40 mm 24/V系列(全片组件)...