Advertisement

Quick Links

Bobcat-640-GigE&CL Camera
Company confidential.
This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party
without written permission from Xenics.
Xenics nv
Ambachtenlaan 44
BE-3001 Leuven  Belgium
User Manual
ENG-2012-UMN020-R000.12
T +32 16 38 99 00
F +32 16 38 99 01
www.xenics.com
User Manual
Bobcat-640-GigE&CL Camera
Doc Ref: ENG-2012-UMN020
XF-104_02/20-01-2012
Page 1 of 24
Issue: R000.12
Date: 29/10/2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bobcat-640-GigE Industrial and is the answer not in the manual?

Questions and answers

Summary of Contents for Xenics Bobcat-640-GigE Industrial

  • Page 1 Bobcat-640-GigE&CL Camera ENG-2012-UMN020-R000.12 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv T +32 16 38 99 00...
  • Page 2 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics.
  • Page 3: Revision History

    Table 2.1 & 2.2 Updated Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv T +32 16 38 99 00...
  • Page 4: Table Of Contents

    6.3. Connect the Camera via Xeneth ............... 22 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 5 7.6. Appendix G ....................... 24 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv T +32 16 38 99 00...
  • Page 6: List Of Abbreviations

    Short Wave Infrared Xenics Short Wave Module Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv T +32 16 38 99 00...
  • Page 7: List Of Figures

    Figure 6-3 Camera properties settings tab ..............23 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 8: List Of Tables

    Table 4-4 Camera Link connector (base) pin assignment ..........20 Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics.
  • Page 9: Introduction

    Chapter lists the appendices. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv T +32 16 38 99 00...
  • Page 10: Reference Documents

    Warning: This symbol highlights important instructions. These instructions must be followed to avoid malfunctions! Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 11: Safety Warnings

    We declare, under our sole responsibility, that the previously described Bobcat cameras areconform to the CE directives. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 12: Contact Information

    Please visit our website for more contact details: www.xenics.com Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 13: Mechanical & Electrical Specifications

    Peak Value Typical value, measured at 25°C FPA temperature Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 14: Bobcat-640-Gige & Cl Specifications

    The design and specifications for the products described above may change without notice. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 15: Optical Interface

    Repeat stage 2 until the lens is clean. Use a new lens tissue each time! Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics.
  • Page 16: Electrical Interface

    Table 4-1 Electrical interface specifications for Bobcat-640-GigE, CL Interface Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 17: Power Interface

    (Hirose HR10-7P-4P(73)). Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 18: Trigger Interface

    For more information on the trigger configuration see chap. (Ref. 5). Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 19: Gige Interface

    European Machine Vision Association'sGenICam™. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 20: Camera Link Interface

    The clock rate is 40 MHz with one tap & 16 bit/pixel. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 21: Software Installation

    After the SDK installation, the SDK manual, together with the samples and header files can be found in the C:\Program Files\Xeneth\SDK directory. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 22: Getting Started

    Figure 6-1 Xeneth shortcut Figure 6-2 Connection dialog - settings Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 23: Figure 6-3 Camera Properties Settings Tab

    More information can be found in (Ref. 5). Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...
  • Page 24 640-GigE are described in more detail in (Ref. Company confidential. This document is the property of Xenics. It may not be reproduced – completely or partially – or passed to a third party without written permission from Xenics. Xenics nv...