INSTALLATION AND USE INSTRUCTIONS TF21/24R/T FEEDING AND CONTROL UNIT TF41/44R/T FOR 24VDC / 230VAC MOTORS P/N 8P5021 VER.1.0 REV.07.04 BEFORE INSTALLING AND USING THE DEVICE, IT IS COMPULSORY FOR THE INSTALLER AND THE USER TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.
Declares that the electric device called: FEEDING AND CONTROL UNIT FOR 24VDC/230VAC MOTORS Type: TF Models: TF21 - TF21R/T - TF24 - TF24R/T 24VDC TF41 - TF41R/T - TF44 - TF44R/T 230VAC Serial No.: see rating plate and CE marking applied on the device...
TF21/44R/T GENERAL REMARKS -2 2.1- GENERAL INSTRUCTIONS BEFORE INSTALLING AND USING THE DEVICE, IT IS COMPULSORY THAT THE INSTALLER AND THE USER CAREFULL Y READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS. THIS MANUAL IS INTEGRAL PART OF THE DEVICE AND MUST COMPULSORILY BE PRESERVED FOR FUTURE REFERENCE.
3- TECHNICAL DESCRIPTION TF21/44R/T 3.1- RATING PLATE AND "CE" MARKING The CE marking certifies the compliance of the machine with the essential safety and health requirements foreseen by the product European Directives. The rating plate is an adhesive plate in polyester, silk-screen printed in black, having the following size: L=36 mm - H=50 mm.
TF21/44R/T TECHNICAL DESCRIPTION -3 3.2- DENOMINATION OF THE COMPONENTS AND DIMENSIONS Fig.2 Dimensions in mm WIND 230V - 50Hz MAINS SENSOR RPR RAIN SENSOR CONTROLS OF ALL MOTORS CONNECTED FEEDING AND CONTROL UNIT SENSOR CONTROLS OF SINGLE OUTPUTS 24Vdc/230Vac MOTORS...
Tab.1 3.4- DESTINATION OF USE THE DEVICE HAS BEEN DESIGNED AND MANUFACTURED ONLY TO FEED AND CONTROL "ORIGINAL TOPP" MOTORS: WINDOW AUTOMA TION ACTUATORS - MOD. C20 - ACK4 - SL60 - C30 - C40. VER.1.0 INSTALLATION AND USE INSTRUCTIONS...
TF21/44R/T TECHNICAL DESCRIPTION -3 3.5- USE LIMITS The device has been designed and manufactured exclusively for the destination of use given in par.3.4, therefore, any other type of use is strictly forbidden in order to assure in any moment the safety of the installer and of the user, as well as the efficiency of the device itself.
4- SAFETY TF21/44R/T 4.1- PROTECTIONS AGAINST ELECTRIC HAZARD The device is protected against electric hazard due to direct and indirect contacts. The protection measures against direct contacts aim at protecting people against hazards due to contact with active parts, usually live parts; while the protection...
TF21/44R/T INSTALLATION -5 5.1- GENERAL INSTRUCTIONS THE DEVICE INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION. BEFORE CONNECTING THE MOTORS (ACTUATORS) TO THE FEEDING AND CONTROL UNIT, VERIFY THAT THEY ARE CORRECTLY INSTALLED ON THE FRAMES IN COMPLIANCE WITH THE RELATED "INSTALLATION AND USE INSTRUCTIONS".
5- INSTALLATION TF21/44R/T 5.3- INSTALLATION OF THE POWER SUPPLY UNIT BEFORE INSTALLING THE FEEDING UNIT PERFORM THE CORRECT INSTALLATION OF THE SENSORS (SEE PAR.5.2) AND THE WIRING OF THE CONNECTION WIRES OF THE SAME. 1) Open the package (par.3.6) and extract the various components;...
TF21/44R/T INSTALLATION -5 5.4- TRIPPING OF THE SENSORS • In order to let the rain sensor trip, it is sufficient to touch with a finger for some second the sensitive part (there is not hazard of electric shock since the device is protected and works at low voltage).
Page 14
5- INSTALLATION TF21/44R/T DIP-switch Speed 5 km/h - (2,083 Hz) 10 km/h - (4,167 Hz) 15 km/h - (6,250 Hz) 20 km/h - (8,333 Hz) 25 km/h - (10,417 Hz) 30 km/h - (12,500 Hz) 35 km/h - (14,583 Hz) 40 km/h - (16,667 Hz) Tab.2...
Page 15
TF21/44R/T INSTALLATION -5 7) The brightness (sun) sensor requires to disable the controls of the rain and wind sensors for the outputs M5 and M6 by means of the “DIP-switch” No.6, which has to be on “OFF” position. The brightness sensor can have two opposite functions;...
5- INSTALLATION TF21/44R/T 5.7- PROGRAMMING OF REMOTE ELECTRONIC CONTROL MOD. F33. THIS CHAPTER DESCRIBES THE PROGRAMMING OF THE "433 MHz RADIO CONTROL" MOD. F33. The green LED DL1 blinks every time the receiver within the feeding unit receives a valid code from the radio control, even if it has not been programmed. In this way, it is possible to have more information on the possible malfunctions of the system.
TF21/44R/T INSTALLATION -5 To enable a remote control proceed as follows: • Press SP2 until the RED LED DL2 lights. Then release it. • Press any key of the remote control that you wish to enable. When the receiver receives the signal from the remote control, the LED DL2 switches off.
IT IS FORBIDDEN TO PERFORM THE CONNECTION OF THE FEEDING AND CONTROL UNIT TO THE EARTHING PLANT. THE FEEDING AND CONTROL UNITS MOD. TF21 AND TF24 CAN BE SUPPLIED ALSO BY A 24V DC EXTERNAL SOURCE BY MEANS OF THE "ORIGINAL TOPP" FEEDER MOD.
Page 19
TF21/44R/T INSTALLATION -5 Wiring diagram Mod. TF21 230V ~ 50Hz Connection to the feeder with buffer batteries AL TF Remote control programming push-button YELLOW BLUE WHITE BLUE Manual control BROWN (A=OPEN - C=CLOSE) VER.1.0 INSTALLATION AND USE INSTRUCTIONS REV.07.04...
Page 20
5- INSTALLATION TF21/44R/T Wiring diagram Mod. TF24 Motors No.1 and 2 window 230V ~ 50Hz opening/closing External feeder Motors No.3 and 4 window module terminal opening/closing board with buffer or, alternatively, internal batteries AL TF curtain or roller shutter motors...
Page 21
TF21/44R/T INSTALLATION -5 INSTALLATION -5 Wiring diagram Mod. TF41 230V ~ 50Hz Remote control programming push-button BROWN BLUE WHITE BLUE YELLOW Single manual (A=OPEN C=CLOSE) VER.1.0 INSTALLATION AND USE INSTRUCTIONS REV.07.04...
Page 22
5- INSTALLATION TF21/44R/T Wiring diagram Mod. TF44 M 230Vac 230V ~ 50Hz Remote control programming push-button General control Local control (A=OPEN C=CLOSE) VER.1.0 INSTALLATION AND USE INSTRUCTIONS REV.07.04...
TF21/44R/T USE AND OPERATION -6 6.1- USE OF THE DEVICE THIS FEEDING UNIT CAN BE USED EXCLUSIVELY BY A USER ACTING IN CONFORMITY WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL. BEFORE USING THIS FEEDING UNIT, THE USER MUST CAREFULL Y READ AND UNDERSTAND THIS HANDBOOK IN ALL ITS PART.
7- DEMOLITION TF21/44R/T 7.1- GENERAL INSTRUCTIONS THE DEMOLITION OF THE FEEDING UNIT MUST OCCUR IN COMPLIANCE WITH THE LAWS IN FORCE ON ENVIRONMENT PROTECTION. DIFFERENTIATE THE PARTS MAKING UP THE FEEDING UNIT ACCORDING TO THEIR DIFFERENT MATERIAL TYPE (PLASTIC, ALUMINIUM, ETC.).
Page 25
TF21/44R/T REMARKS VER.1.0 INSTALLATION AND USE INSTRUCTIONS REV.07.04...
Page 26
REMARKS TF21/44R/T VER.1.0 INSTALLATION AND USE INSTRUCTIONS REV.07.04...
Page 27
The products must be installed and used in compliance with the technical features and the instructions given by TOPP, as well as according to the safety regulations and the standards that rule the installation and employment of the electrical devices in the country where the products are installed and used.
Need help?
Do you have a question about the TF44 and is the answer not in the manual?
Questions and answers